4.0 Hardware Descriptions and Specifications
- 38 -
FIGURE 4-12: Power Supply Unit Latch Open - Installation and Removal
IEC Power connection
Power Supply Tray Thumb Screw
Power Supply Tray Latch (open position)
FIGURE 4-13: Power Supply Unit Latch Locked - Operating
Power Supply Tray Latch (locked position)
FIGURE 4-14: Power Supply Unit Rack Connection
SG-System 5 Rack Power Connection
Electrical Specifications:
l
Input voltage range: 100 - 240VAC
l
Frequency: 50/60Hz
l
Input current:8A maximum (RMS) @ 100VAC
l
Wattage: 600W
In a redundant SG-System 5 configuration, a secondary SG-PSU5-600 can be inserted in the secondary slot. In the event of a SG-PSU5-600 failure,
the redundant SG-PSU5-600 automatically assumes operation. These modules are Hot Swappable (can be removed/replaced while the system is in oper-
ation) if a working redundant SG-PSU5 is installed in the other power supply bay.
NOTE: A SG-PSU5-600 and a SG-PSU5-250 cannot be used in the same SG-MLRF5
4.6.1 SG-PSU5-600 Installation
To replace the SG-PSU5-600 in a SG-MLRF5, follow these steps:
NOTE: If a SG-PSU5-600 is already installed, skip steps 1-3.
1. Pull out the IEC cable from the SG-PSU5.
2. Lift the red safety tab and unfasten the thumb screw.
3. Pull the SG-PSU5 out of the SG-MLRF5.
4. Slide the new SG-PSU5 into the SG-MLRF5.
5. Fasten the thumb screw and slide the red safety tab down.
6. Plug in the IEC cable.
S
G
-S
ys
te
m
5
O
pe
ra
ti
ng
M
anua
l
Summary of Contents for SG-System 5
Page 69: ...6 0 Options 69 FIGURE 6 2 Flow Diagram for Fallback Mode 1 SG System 5 Operating Manual ...
Page 70: ...6 0 Options 70 FIGURE 6 3 Flow Diagram for All Mode 2 SG System 5 Operating Manual ...
Page 71: ...6 0 Options 71 FIGURE 6 4 Flow Diagram for IP Fallback Mode 3 SG System 5 Operating Manual ...