HSM2955
1.0
Installation
Guide
To download the full installation manual and register your product,
visit
or scan the QR code to the right.
1. Introduction
This installation manual shall be used in conjunction with the installation manual of the alarm con-
trol panel to which the HSM2955(R) is connected. Disconnect power and telephone line before
installing the module.
1.1 Specifications
Operating Temperature Range
-10° to 55°C (14° to 131 °F); UL/ULC: 0° - 49°C
Humidity
up to 93% RH, non condensing
Operating Voltage (RED, BLK) from compatible
control panel
11.3 to 12.5 VDC (max)
Current Draw (board only)
100mA (max)
Current Draw (active/max stations)
500mA (max
with
2 PC5964E
connected);
500mA (max with 4 PC5961E connected)
AUX Output
7.6 - 8.6 VDC/400mA
PC5961E (small audio station)
30mA(min) - 100mA (max)
PC5964E (large audio station)
30mA(min) - 190mA (max)
Wiring Distance (all audio stations)
152m (500ft)
Dimensions
21.7cm x 5.3cm (8.55” x 2.075”)
Microphone Audio Range:
PC5961E
7.62m (25ft)
PC5964E
15.2m (50ft)
Compatibility:
Control Panels
HS2016, HS2032, HS2064, HS2128
Communicators
TL2803GR, TL2803G, 3G2080R, 3G2080,
3G8080(I), CD8080(I)
1.2 Out of the Box
The HSM2955(R) kit includes the following:
l
1 HSM2955(R) Audio Verification Module
l
5 Stand-offs
l
1 Audio Header Cable
l
1 HSM2955(R) Installation Manual
l
1 HSM2955(R) User Guide
Figure 1: Installation in the Cabinet
WARNING:
HIGH VOLTAGE! Disconnect AC power
and telephone lines prior to servicing.
CAUTION!
Do not route wiring over the HSM2955(R)
module. Maintain at least 1” (25.4mm) separation. A min-
imum distance of 1/4”(6.4 mm) must be maintained at
all points between power limited and non- power lim-
ited wiring. All circuits are classified for UL install-
ations as Power Limited/Class II Power Limited,
except for the battery leads which are not power lim-
ited. Do not route any wiring over circuit boards.