Figure 2 - TL8803GI-IL2 backplate
TL880
A: Mounting holes
B. Wall tamper plate
C: Breakaway tabs
D: RS422 cable
E: Ethernet cable
4.
Secure the backplate to the wall using the four mounting holes. (See figure 2)
Note : Use all four screws provided. Use the plastic anchors if mounting on drywall. If using the tamper,
secure the tamper plate to the wall with a screw.
Step 1: Enable module
For the Alarm.com module to communicate with the panel, section [382] option 5 at the panel must be set to
ON. This section is OFF by default and must be enabled for the system to function properly. This should be
done before connecting the PC-Link cable to power up the module to ensure all initialization commands are
processed properly.
Step 2: Connect the TL8803GI-IL2
Caution:
Ensure that the alarm panel is fully powered down (i.e., AC and battery disconnected) prior to con-
necting the TL8803GI-IL2.