Panel settings changed automatically
Some panel settings are changed automatically when the module is connected to the control panel. These set-
tings should not be altered. They are:
Section
Option
Value
Description
015
6
OFF
Master code is not changeable and must be
OFF to ensure the module communicates the
correct master code.
017
6
OFF
Daylights saving time must be disabled to
ensure panel time is accurate.
019
6
Set according to
dealer's Alarm.com
setting
Enables Duress Code changes from
Alarm.com.
024
5
OFF
Realtime clock must be disabled to ensure
panel time is accurate.
377
Swinger Shutdown
(Maintenance)
010
Swinger Shutdown for maintenance signals
must be set to 010 to ensure trouble
notifications can be sent.
377
AC Failure
Communication Delay
Random value between
001 and 030
AC Failure Communication Delay should be
set between 001 and 030 to ensure
notifications for power failures are received.
377
Wireless Device Low
Battery Transmission
Delay
001
Wireless Device Low Battery Transmission
Delay should be set to 001 to ensure
notifications for low batteries are received.
380
1
ON
Communications must be enabled for the
module to communicate with the panel.
380
2
OFF
System should transmit alarm restores
immediately when the zone is restored.
380
5
OFF
The redundant communications method must
be set as backup.
382
6
OFF
AC Failure Transmission Delay should be in
minutes.
804 [sensor #]
003
Five minute delay [07]
High Traffic Shutdown should be set to five
minutes for devices being used with
Alarm.com's Activity Monitoring.
Note:
This feature may reduce the battery life
of wireless PIR sensors. In order to avoid this,
hardwired PIR sensors may be used instead.
Clock
The TL8803GI-IL2 module sets the panel clock when it connects to Alarm.com and then updates it every 18
hours. It is important to select the correct panel time zone on the Alarm.com website, or the panel time will
not be accurate. If a system is powered up before the customer account has been created, the time zone will
default to
Eastern Standard Time.
- 15 -
Installation
Summary of Contents for DSC TL8803GI-IL2
Page 27: ...TL8803GI IL2...
Page 29: ...29 49 51 51...
Page 30: ...30...
Page 31: ...31...
Page 37: ...3 HSPA 4 HSPA A PCLink2 B C Ethernet D 100 30 E PCL 422 PCLink F HSPA HSM2204 2300 37...
Page 43: ...TL8803GI IL2 Alarm com 18 Alarm com 43...
Page 50: ...HSPA SN SIM Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 Z Wave 1 1 Alarm com Z Wave 50...
Page 53: ...2019 Tyco 1 800 387 3630 905 760 3000 www dsc com Tyco Tyco 29010718R002...