background image

TFP910

Page 11 of 20

2

1

1

1

1

1

1

3

2

1

1

1

1

1

1

1

1

2

2

QTY.

1

2

1

1

1

2

2

2

1

2

1

QTY.

1

1

. . . .

. . . . .

. . . .

. . . . . . . . . . .

. . . .

. . . . . . . . .

. .

. . . . .

. . . . .

. . . .

. . . . . . . .

. . . . .

. . . . .

. . . . . . . . . .

. . . . . . . . .

. . . . . . .

.

. .

. .

. . . . . . . . . . . .

. . . . . . . . . . . . .

. . . . . . . . . . . . . .

. . . . . . . . . . . .

. . . . . . . . .

. . . . . . . . .

. . . . .

. . . . .

. . . . .

. . . . .

. . . . . . . .

. . . .

. . . . .

28

17

6

10

8

9

7

21

19

20

18

32

30

31

29

3

5

4

2

1

NO.

14

16

15

12

13

11

25

27

26

23

24

NO.

22

CH

3/4" x 1-1/2" Nipple

CH

92-210-2-005

Restriction Assembly

3/4" x 1/4" x 3/4" Tee

92-211-1-005

92-211-1-003

92-343-1-007

46-048-1-009

Drip Funnel Connector

Drip Funnel

Drip Funnel Bracket

2" Angle Valve

1/4" x 1-1/2" Nipple

1/2" x Close Nipple

3/4" x 3/4" x 1/2" Tee

CH

CH

CH

2" x 3" Nipple

3/4" x 4-1/2" Nipple

3/4" x 3" Nipple

3/4" x 2-1/2" Nipple

CH

CH

CH

CH

92-343-1-005

46-049-1-005

46-005-1-002

52-353-1-005

46-047-1-004

DESCRIPTION

Water Pressure Gauge

300 psi/ 2000 kPa

3/4" Swing Check Valve

1/4" Gauge Test Valve

1/2" Y-Strainer

1/2" Globe Valve

P/N

1/2" 90° Elbow

1/2" 45° Elbow

1/2" Tee

3/4" Union

1/2" Union

1/4" Plug

CH

CH

CH

CH

CH

CH

1/2" x 6-1/2" Nipple

3/4" x Close Nipple

1/2" x 3-1/2" Nipple

1/2" x 4-1/2" Nipple

1/2" x 2" Nipple

DESCRIPTION

CH

CH

CH

CH

CH

P/N

CH

1/2" x 1/2" x 3/4" Tee

1/2" x 1-1/2" Nipple

CH

All Fittings and Nipples are galvanized

(Standard Order).

Install subassemblies in alphabetical order.

NOTES:

3.

1.
2.

CH: Common Hardware.

DRIP

FUNNEL

2 INCH NPT

CONNECTION

TO DRAIN

1-1/4 INCH NPT

CONNECTION

TO DRAIN

1/2 INCH NPT

CONNECTION

FOR WATERFLOW

PRESSURE ALARM

SWITCH

1/2 INCH NPT

CONNECTION

FOR WATERFLOW

PRESSURE ALARM

SWITCH

RESTRICTION

ASSEMBLY,

SEE FIGURE 3

3/4 INCH NPT

CONNECTION FOR

WATER MOTOR

ALARM

3/4 INCH NPT

CONNECTION FOR

WATER MOTOR

ALARM

MAIN

DRAIN VALVE

(NORMALLY

CLOSED)

ALARM

TEST VALVE

(NORMALLY

CLOSED)

MODEL RC-1

RETARD

CHAMBER

ORDERED

SEPARATELY

(FOR VARIABLE

PRESSURE

SYSTEMS)

SYSTEM

PRESSURE

GAUGE

SUPPLY

PRESSURE

GAUGE

MODEL AV-1

ALARM VALVE,

8 INCH (DN200)

FLANGE x GROOVE

SHOWN

LOCATION

FOR OPTIONAL

ELECTRICALLY

SUPERVISED

N.O. ALARM

CONTROL

VALVE

LOCATION

FOR OPTIONAL

ELECTRICALLY

SUPERVISED

N.O. ALARM

CONTROL

VALVE

G

E

H

A

F

D

C

B

8

9

10

7

15

21

16

6

22

21

32

21

17

26

5

16

24

25

12

4

24

25

14

23

20

28

19

18

27

29

30

13

3

31

27

18

20

1

11

2

1

2

11

FIGURE 5 (3 OF 3) 

VERTICAL OPEN DRAIN TRIM — SPECIAL ORDER — SEMI-PREASSEMBLED 

FOR 8 INCH (DN200) MODEL AV-1-300 ALARM CHECK VALVES (P/N 52-204-4-955)

Summary of Contents for AV-1-300

Page 1: ...herein must be installed and maintained in com pliance with this document as well as with the applicable standards of the National Fire Protection Association NFPA in addition to the standards of any...

Page 2: ...es 4 6 8 Inch NR Clapper See b 92 200 1 423 92 200 1 623 92 200 1 823 Hex Bolt Handhole Cover 2 1 2 Inch Valve x 1 1 4 Long CH DESCRIPTION REF VALVE PARTS 1 2 13 UNC 2A 6 Inch Valve x 1 3 4 Long CH 1...

Page 3: ...95 0 0 91 23 0 11 42 290 0 5 50 139 7 0 75 19 0 5 00 127 0 5 51 140 0 0 87 22 0 0 71 18 0 0 71 18 0 0 87 22 0 0 87 22 0 0 71 18 0 0 75 19 0 4 Inch DN100 6 Inch DN150 8 Inch DN200 2 1 2 Inch DN65 4 8 8...

Page 4: ...e TYCO Model AV 1 300 Alarm Check Valves consideration must be given to the dis posal of the large quantities of water that may be associated with draining the system or performing a flow test Valves...

Page 5: ...ch line at the point most remote from the alarm valve The vent line should be connected to the top of a cross main or to the end of a branch line and be located at the highest level of a multi level i...

Page 6: ...ple 1 4 x 2 1 2 Nipple CH DESCRIPTION 1 1 4 INCH NPT CONNECTION TO DRAIN 1 2 INCH NPT CONNECTION FOR WATERFLOW PRESSURE ALARM SWITCH RESTRICTION ASSEMBLY SEE FIGURE 3 3 4 INCH NPT CONNECTION FOR WATER...

Page 7: ...2 1 2 x 4 1 2 All Fittings and Nipples are galvanized Standard Order Install subassemblies in alphabetical order NOTES 3 1 2 CH Common Hardware 2 INCH NPT CONNECTION TO DRAIN 1 2 INCH NPT CONNECTION...

Page 8: ...ESCRIPTION CH CH CH CH CH CH P N CH 1 2 x 1 2 x 3 4 Tee All Fittings and Nipples are galvanized Standard Order Install subassemblies in alphabetical order NOTES 3 1 2 CH Common Hardware 2 INCH NPT CON...

Page 9: ...6 048 1 007 92 304 1 017 P N 1 4 90 Elbow 1 4 Plug CH CH All Fittings and Nipples are galvanized Standard Order CH Common Hardware NOTES 1 2 SUPPORT BRACKET SUPPORT BAR EXTERNAL BY PASS TUBE ALARM TES...

Page 10: ...ommon Hardware Select Appropriate Nipple Sizes per AV 1 Alarm Check Valve Size 4 Inch DN100 29 1 2 x 1 1 2 30 1 2 x 3 1 2 Nipple Number 1 2 x 2 1 2 1 2 x 4 1 2 6 Inch DN150 2 INCH NPT CONNECTION TO DR...

Page 11: ...3 4 Tee 1 2 x 1 1 2 Nipple CH All Fittings and Nipples are galvanized Standard Order Install subassemblies in alphabetical order NOTES 3 1 2 CH Common Hardware DRIP FUNNEL 2 INCH NPT CONNECTION TO DRA...

Page 12: ...TION TO DRAIN 1 2 INCH NPT CONNECTION FOR WATERFLOW PRESSURE ALARM SWITCH RESTRICTION ASSEMBLY SEE FIGURE 3 3 4 INCH NPT CONNECTION FOR WATER MOTOR ALARM 3 4 INCH NPT CONNECTION FOR WATER MOTOR ALARM...

Page 13: ...CH CH CH CH CH CH CH CH CH CH P N 2 INCH NPT CONNECTION TO DRAIN 1 2 INCH NPT CONNECTION FOR WATERFLOW PRESSURE ALARM SWITCH RESTRICTION ASSEMBLY SEE FIGURE 3 3 4 INCH NPT CONNECTION FOR WATER MOTOR A...

Page 14: ...7 8 225 G F E D G x G F x G C A B F x G G x G B A D E C F G With RC 1 D E F G B C Dimension A Without RC 1 Dimensions in Inches and mm 16 1 2 419 8 7 8 225 10 1 2 267 12 1 4 311 16 1 2 419 10 1 2 267...

Page 15: ...2 394 12 1 2 318 10 1 4 260 10 1 2 267 10 1 2 267 10 254 10 254 19 483 D F x G F G E D F x F D G x G C A B 11 1 2 292 11 1 4 286 11 1 2 292 12 1 4 311 2 3 4 70 15 1 2 394 12 305 12 305 12 1 4 311 11 1...

Page 16: ...38 19 1 2 495 14 356 C B A E G F G F C A B B C D E G x G F x F F x G E 3 1 2 89 15 1 2 394 16 1 2 419 16 1 8 410 18 1 2 470 3 1 2 89 N A 16 1 2 419 16 1 8 410 15 3 4 400 14 356 12 305 14 356 12 305 D...

Page 17: ...es to flow from the alarm line drain Step 6 Clean the 1 2 inch Strainer located in the valve trim as well as the 3 4 inch Strainer located at the connection to the water motor alarm as applicable Be s...

Page 18: ...lve slowly remove the plug from the supply pres sure gauge test valve to relieve the supply pressure and then slowly open the union in the externally mounted bypass Step 3 Check for leakage past the B...

Page 19: ...057 8 Inch P N 52 204 4 058 Accessories Order the following accessories as applicable Model RC 1 Retard Chamber P N 52 211 1 002 Required for variable pressure water sup ply conditions Alarm Vent Tri...

Page 20: ...N 52 203 4 715 JIS Flange x 6 62 inch 168 3 mm Groove O D P N 52 203 4 815 JIS Flange x 6 50 inch 165 1 mm Groove O D P N 52 203 5 815 6 50 inch 165 1 mm Groove O D x 6 50 inch 165 1 mm Groove O D P N...