TYAN Tank TA26 B5380 Service Manual Download Page 4

  

 

3.4.2 Removing the Motherboard . . . . . . . . . . . . . . . . . . . . . . . . 40

3.5 Replacing the Slim DVD-ROM  . . . . . . . . . . . . . . . . . . . . . . . . . . 41
3.6 Replacing the LED Control Board . . . . . . . . . . . . . . . . . . . . . . . . 43
3.7 Replacing the Backplane. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45

3.7.1 Backplane Features for TA26-B5380  . . . . . . . . . . . . . . . . 47
3.7.2 Backplane Connector Pin Definitions . . . . . . . . . . . . . . . . 49

3.8 Replacing the System Fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
3.9 Replacing the Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

3.9.1 Standard Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
3.9.2 Optional 1+1 Redundant Power Supply  . . . . . . . . . . . . . . 55

Appendix I: BIOS Differences

Appendix II: Cable Connection Tables

Summary of Contents for Tank TA26 B5380

Page 1: ...Tank TA26 B5380 Service Engineer s Manual...

Page 2: ......

Page 3: ...in 15 2 0 2 Work Area 15 2 0 3 Tools 15 2 0 4 Precautions 16 2 1 Rack Mounting 17 2 1 1 Installing the Server in a Rack 17 2 2 Installing Motherboard Components 22 2 2 1 Removing the Chassis Cover 22...

Page 4: ...cing the Backplane 45 3 7 1 Backplane Features for TA26 B5380 47 3 7 2 Backplane Connector Pin Definitions 49 3 8 Replacing the System Fan 53 3 9 Replacing the Power Supply 54 3 9 1 Standard Power Sup...

Page 5: ...duct descriptions and or specifications at any time without notice In no event will TYAN be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other...

Page 6: ...ent into an outlet on a circuit different from that of the receiver Consult the dealer on an experienced radio television technician for help Notice for Canada This apparatus complies with the Class B...

Page 7: ...s a table of key components and provides block diagrams of the system Chapter 2 Covers procedures on installing the CPU mem ory modules and hard drives Chapter 3 Covers removal and replacement procedu...

Page 8: ...his pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in...

Page 9: ...puting high bandwidth memory design and a lightning fast PCI X bus implementation The Tank TA26 B5380 not only empowers your company in today s demanding IT environment but also offers a smooth path f...

Page 10: ...2 Chapter 1 Overview 1 2 Product Models Model HDD Bays Backplane Power Supply B5380T26V8H 8 8 port SAS SATA Single 600W B5380T26V8HR 8 8 port SAS SATA 600W 1 1 redundant...

Page 11: ...of H W monitoring Auto configuration of hard disk types Multiple boot options 48 bit LBA support Expansion Slots One 1 PCI E x16 slot w x8 signal One 1 PCI E x8 slot w x4 signal One 1 PCI E x16 slot...

Page 12: ...ts TYAN Server Management TSM Optional TYAN SMDC M3291 IPMI v2 0 compliant remote server management kit Power Supply EPS 12V 2U 600W with PFC for B5380T26V8H EPS 12V 2U 600W 1 1 redundant power with P...

Page 13: ...s Component Description Industry standard 2U chassis 8 hot swap HDD bays TYAN Tempest i5000PX S5380G2NR mother board pre installed Slim DVD ROM drive pre installed LED and USB control board pre instal...

Page 14: ...browse to TYAN s Web site for service http www tyan com The Web site also provides information on other TYAN prod ucts plus FAQs compatibility lists BIOS settings and more 1 x TYAN Driver CD Power Ca...

Page 15: ...Chapter 1 Overview 7 Screw Pack Sliding Rail Brackets FDD Power Cable TYAN Logo...

Page 16: ...setup B5380T26V8HR is also available In both cases the output voltage is the same Reset switch USB ports Warning LED HDD activity LED LAN LEDs Hard Drive Bay x 8 DVD ROM drive HDD Tray Activity LEDs P...

Page 17: ...ing OFF HDD ready HDD access activity HDD not ready SATA HDD Green OFF Blinking OFF HDD access activity No disk activity LED Color State Description LAN1 LAN2 Linkage Activity Left Side Green Green OF...

Page 18: ...10 Chapter 1 Overview 1 5 4 Motherboard Layout...

Page 19: ...use only J28 IPMB Connector J7 J44 J68 Chassis Fan Connectors J7 FAN1 J44 FAN3 J68 FAN2 J39 J40 CPU Fan Connectors J39 CPUFAN1 J40 CPUFAN0 J70 Chassis LCD Module Interface Header J76 IDE Connector J7...

Page 20: ...12 Chapter 1 Overview 1 5 6 System Block Diagram...

Page 21: ...nnector 3 Power Supply 4 CPU0 CPU1 5 SAS SATA Backplane 6 LED Control Board Cable 7 Eight 8 SAS SATA HDDs 8 DVD ROM Cable 9 System Fans 10 SAS SATA Cables 6 11 PCI E Slot 12 PCI E Slot 13 PCI E Slot 1...

Page 22: ...14 Chapter 1 Overview...

Page 23: ...ntainers to keep small components separated Putting all small components in separate containers prevents them from becoming lost Adequate lighting and proper tools can prevent you from accidentally da...

Page 24: ...of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always p...

Page 25: ...1 1 Installing the Server in a Rack Follow these instructions to mount the TA26 B5380 into an industry standard 19 rack NOTE Before mounting the Tank TA26 B5380 in a rack ensure that all internal com...

Page 26: ...es to each side of TA26 B5380 as shown using two 2 M4L6 S10C screws A from the supplied screws kit 2 Attach the inner rails both sides of the unit using nine 9 M4 L5 screws C on each side Installing O...

Page 27: ...Chapter 2 Setting Up 19 2 Secure the outer rail to the rack using 2 brackets and M6 screws B for each side Secure the mounting brack ets from inside not outside of the rack...

Page 28: ...er 2 Setting Up Rackmounting the Server 1 Draw out the middle rail to the latch position 2 Lift the unit and then insert the inner slide rails into the middle rails 3 Push the unit in and press the la...

Page 29: ...h the whole system into the rack 5 Secure the mounting handles of the unit to the rack Note To avoid injury it is strongly recommended that two people lift the TA26 B5380 into the place while a third...

Page 30: ...stall components on to the motherboard including CPU memory modules and PCI card 2 2 1 Removing the Chassis Cover Follow these instructions to remove the Tank TA26 B5380 chassis cover 1 Turn the screw...

Page 31: ...ting Up 23 2 2 2 Installing the CPU Follow these instructions to install the CPU 1 Remove the cover on the CPU socket 2 Lift up the CPU lever to unlock the socket 3 Open the socket in the direction as...

Page 32: ...the CPU in the CPU socket ensuring that pin 1 is located as shown below 5 Close the cover and press the CPU socket lever down to secure the CPU 6 Place the fan and heatsink on top of the CPU and attac...

Page 33: ...Chapter 2 Setting Up 25 7 Attach the fan power cable to the connector on the motherboard as shown 8 Repeat these steps when installing a second CPU...

Page 34: ...rd 2 Press the memory slot locking levers in the direction of the arrows as shown below 3 Align the memory module with the slot The module has indentations that align with notches in the slots 4 Inser...

Page 35: ...IMMA0 X X X X DIMMA1 X DIMMB0 X X X DIMMB1 X DIMMC0 X X DIMMC1 X DIMMD0 X X DIMMD1 X Note 1 X indicates a populated DIMM slot 2 Always install memory beginning with DIMMA0 You can choose to install si...

Page 36: ...CI E card slots 2 x PCI X card slots Follow these instructions to install any of the above kinds of PCI cards 1 Unscrew the bracket covering the PCI card slots as shown 2 Lift up the card slot cover 3...

Page 37: ...0 supports up to eight serial SAS SATA hard drives Follow these instructions to install a hard drive 1 Press the locking lever latch in the direction shown by the arrow below The latch will pop open 2...

Page 38: ...30 Chapter 2 Setting Up 4 Remove the base 5 Place a hard drive into the drive tray 6 Screw the hard drive in place using 4 HDD screws...

Page 39: ...Chapter 2 Setting Up 31 7 Reinsert the tray into the bay and press the locking lever to secure...

Page 40: ...ructions to install a floppy disk drive in the TA26 B5380 1 Remove the top left hand drive tray from the TA26 B5380 as shown Note The top left hand drive bay is the only bay that can accommodate a flo...

Page 41: ...he floppy disk drive from the front 3 Plug the floppy disk drive cable into the port on the back of the floppy disk drive Thread the cable out through the back of the empty drive bay 4 Slide the flopp...

Page 42: ...34 Chapter 2 Setting Up Note To release the floppy disk drive from the drive bay you will need to press the release catch inside the chassis...

Page 43: ...e malfunc tions Use containers to keep small components separated Putting all small components in separate containers keeps them from becoming lost Adequate lighting and proper tools can prevent you f...

Page 44: ...tal body of any other grounded appli ance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboar...

Page 45: ...hart outlines the disassembly procedure Note The Tank TA26 B5380 should be always powered off before disassembly Rear Components Chassis top cover Mainboard DIMMs CPU heatsink assembly PCI card Mainbo...

Page 46: ...Cover Before replacing any parts you must remove the chassis cover Follow these instructions to remove the cover of the Tank TA26 B5380 chassis cover 1 Remove the screw on the back side Then slide th...

Page 47: ...replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all motherboard cabling 1 Disconnect power cables 2 Disconnect the DVD R...

Page 48: ...nents 3 4 2 Removing the Motherboard After removing all of the aforementioned cables follow these instructions to remove the motherboard from the chassis 1 Remove the ten screws securing the motherboa...

Page 49: ...the Slim DVD ROM Follow these instructions to replace the DVD ROM 1 Remove the power data cable from the rear of the DVD ROM drive 2 Press the tab in the direction shown to release the DVD ROM drive...

Page 50: ...ponents 4 Remove the two screws that secure DVD ROM drive to the bracket 5 Replace the DVD ROM drive 6 Secure the DVD ROM to the bracket using two screws Then replace the unit into the drive bay and c...

Page 51: ...ED Control Board Follow these instructions to replace the LED control board 1 Remove the screw securing the LED control board unit to the chassis 2 Remove the connector cables from the backplane 3 Sli...

Page 52: ...om the LED control board USB adapter board 5 Remove the five screws securing the LED control board USB adapter board to the bracket 6 Release the LED control board USB adapter board from bracket After...

Page 53: ...ur TA26 B5380 system 1 Remove all of cables connected to the backplane includ ing fan cables DVD ROM cable Control board cable fan control cable USB cable front panel LED cables power cables and SATA...

Page 54: ...46 Chapter 3 Replacing Pre Installed Components 2 Remove the ten screws to release the backplane 3 Turn the locking keys at the base of the backplane 4 Pull out the backplane...

Page 55: ...1 Backplane Features for TA26 B5380 Front View J35 2x7pin LED J13 29pin SAS J14 29pin SAS J15 29pin SAS J34 2x5pin LED J11 29pin SAS J12 29pin SAS J7 40pin cd rom B J33 2x12pin LED B J5 2x5pin USB J36...

Page 56: ...ear View J1 J2 J3 big 4pin FAN1 4pin J6 TO CD ROM FAN2 4pin J37 small 4pin FAN3 4pin J32 LED B J4 USB OUT J25 J27 J29 J31 7pin secondary J24 J26 J28 J30 7pin primary J38 2x7pin tach and PWM J17 J19 J2...

Page 57: ...D link active 6 LAN2 LED link active 7 Reserved 8 Reserved 9 Reserved 10 Reserved 11 ID LED 12 ID LED 13 W LED 14 W LED 15 M B HDD LED 16 M B HDD LED 17 M B power LED 18 M B power LED 19 M B reset swi...

Page 58: ...W circuit design only It might be different from the system fan name FAN1 FAN2 FAN3 4 pin Fan connector J1 J2 and J3 power big 4 pin connector 25 DIOR 26 VCC 27 IORDY 28 CSEL 29 DMACK 30 VCC 31 INTRQ...

Page 59: ...D LED pin out 1 USB1 power 2 USB2 power 3 USB1 DATA 4 USB2 DATA 5 USB1 DATA 6 USB2 DATA 7 USB1 GND 8 USB2 GND 9 Key pin 10 None 1 5V 2 GND 3 GND 4 12V 1 PLED1 2 GND 3 ALED1 4 ALED1 5 PLED2 6 GND 7 ALE...

Page 60: ...AN tach and PWM pin out 1 PLED6 2 GND 3 ALED6 4 ALED6 5 PLED7 6 GND 7 ALED7 8 ALED7 9 PLED8 10 GND 11 ALED8 12 ALED8 13 None 14 Key 1 FAN1 tach 2 Reserved 3 FAN2 tach 4 Reserved 5 FAN3 tach 6 Reserved...

Page 61: ...these instructions to replace the cooling fans in your TA26 B5380 system 1 Locate the fan connector on the backplane and unplug the fan cable as shown below 2 Take the fan away from the chassis 3 Repl...

Page 62: ...y in your TA26 B5380 system 3 9 1 Standard Power Supply 1 Remove the chassis cover See Removing the Cover on page 38 for more details 2 Detach the power cables from the motherboard and backplane See D...

Page 63: ...If the optional 1 1 redundant power supply is fitted either of the two units can be hot swapped Follow these instructions to replace a single power unit with a redundant power supply unit Note Before...

Page 64: ...2 Remove the screws which fix the bracket to the sides of the redundant power supply casing 3 Screw the bracket to the rear of the power supply casing 4 Insert the redundant power supply casing into...

Page 65: ...lacing Pre Installed Components 57 5 Screw the casing to the chassis exterior 6 Screw the casing to the chassis interior 7 Fix the redundant power supply switch to the chassis rear window with two Hex...

Page 66: ...8 Chapter 3 Replacing Pre Installed Components 8 Insert the new power supply unit and secure by turning the locking screw 9 Re attach all power supply connector cables to the moth erboard and backplan...

Page 67: ...alth Configuration PhoenixBIOS Setup Utility Advanced Hardware Health Configuration Item Specific Help XVoltage Monitoring CPU Fan1 CPU Fan2 System Fan1 System Fan2 System Fan3 CPU1 Temp CPU2 Temp Sys...

Page 68: ...xxxx RPM xxxx RPM xxxx RPM xxxx RPM xx C xxx F xx C xxx F Disabled F1 Help Select Item Change Values F9 Setup Defaults Esc Exit Select Menu Enter Select X Sub Menu F10 Previous Values S5380 B5380 Har...

Page 69: ...TA2 J22 SATA3 J24 SATA4 J26 SATA5 Table 2 System Fan to Backplane System Fan Connects to Backplane Fan 1 FAN1 4 pin connector Fan 2 FAN2 4 pin connector Fan 3 FAN3 4 pin connector Table 3 Power Supply...

Page 70: ...P3 4 pin power cable J3 4 pin connector Table 5 Backplane to Motherboard Backplane Connects to Motherboard J32 LED B J74 J4 USB OUT USB1 USB2 Table 6 Backplane to LED Control Board Backplane Connects...

Page 71: ...s TYAN s website www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memor...

Page 72: ...not cover damages incurred during shipping or failure due to the alteration mis use abuse or improper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase i...

Reviews: