Power LED Definitions
Bicolor
Power Supply condition
Green LED
Amber LED
No AC power to all power supplies
OFF
OFF
Power supply critical event causing a shutdown;
failure, OCP, OVP, Fan Fail, OTP, UVP
OFF
Amber Solid ON
Power supply warning events where the power
supply continues to opeate; high temp (inlet
temperature>51 deg (PMBus reading), or hot spot
temperature >95 deg (PMBus reading), high power,
high current, slow fan (Fan w/- 20% RPM)
OFF Amber
Blinking
@1Hz
AC present Only 12VSB on (PS off) or PS in Smart
Redundant state
Green Blinking
@1Hz
OFF
Output ON and OK
Green Solid ON
OFF
AC cord unplugged or AC power lost with a second
power supply in parallel still with AC input power
OFF
Amber Solid ON