T W I S T E R T R I M M E R . C O M
Solution:
1.
Ensure the Trim Saver and T4 are unplugged and all motors have come to a complete stop.
2.
If
the
fi
lter adapter is too close to a wall, relocate the Trim Saver at least 4 from any wall.
3.
If the adapter has plenty of space, inspect the
fi
lter bags. If they are dirty, clean them.
4.
If
the
fi
lter bags are clean and a Vacuum Bypass is being used, close the Vacuum Bypass.
5.
If
the
fi
lter bags are clean, ensure nothing is blocking the hose. If a block is found,
remove the hose from the T4 and Trim Saver, and remove the blockage.
6.
If nothing is blocking the hose, inspect the gaskets for leaks. If leaks are found, replace
the
gaskets.
7.
If all solu ons so far have failed, clean the impeller:
a.
Remove the hose from the motor assembly inlet.
b.
Remove the 12 screws on the top of the motor assembly (see Fig. 32).
c.
Remove the top of the motor assembly.
d.
Scrape buildup o
ff
the impeller with a plas c scraper.
e.
Wipe the impeller with isopropyl alcohol. Do not use water on the impeller. The
inside of the motor should remain as dry as possible.
Fig. 32
KEEP THE MOTOR AS DRY
AS POSSIBLE TO PREVENT
ELECTRIC SHOCK.
DANGER
!
p g | 2 5
T R O U B L E S H O O T I N G