GAS REQUIREMENTS
–
E
XTREME
G
AS
G
RILL
Each appliance is set and tested at the factory for the type of gas supply to be used. Identify the type of gas,
either natural gas or L.P. gas and make sure that the marking on the data plate (rating plate) matches the gas
supply. The data plate is located on the panel behind the control panel of the grill. Remove the drip tray to
visually access the nameplate label from the front of the grill.
L.P. Gas
If your grill is factory built for L.P., the regulator supplied is set for 11” water column and is for use with L.P.
gas only. The factory-supplied regulator and hose must be used with a 20 lb. L.P. cylinder. For plumb-in
installation (system L.P. installation), the regulator must be changed and a main gas shutoff valve must be
installed. Contact your Twin Eagles, Inc. dealer for a system L.P. regulator.
L.P. Gas Safety Requirement
NEVER USE A RUSTY OR DENTED L.P. CYLINDER.
NEVER USE A CYLINDER WITH A DAMAGED VALVE.
The LP-gas supply cylinder must be constructed and marked in accordance with the
Specifications for LP-gas
Cylinders
of the U.S. Department of Transportation (D.O.T.) or the National Standards of Canada
CAN/CSA-
B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods, and Commission,
as
applicable; and
1.
Provided with a listed overfilling prevention device.
2.
Provided with a cylinder connection device compatible with the connection for outdoor cooking
appliances.
It must be provided with a shut-off valve terminating in gas tank valve outlet. It must include a collar to
protect the cylinder valve. The cylinder supply system must be arranged for vapor withdrawal.
Do not operate the gas grill indoors or in any enclosed area. If the gas grill is not in use, the gas must be
turned off at the supply cylinder. If the grill is to be stored indoors, disconnect the gas supply cylinder and
leave the cylinder outdoors.
When checking for gas leaks, do not use open flame. Use a soapy water solution and apply to pipe joints and
fittings with a brush and check for bubbles. Check flexible hoses for cuts and wear that may affect the safety
before each use. Only the factory supplied hose and regulator must be used. Use only replacement regulator
and hose assemblies specified by Twin Eagles, Inc.
4