TWINBIRD SC-DF25WL Instruction Manual Download Page 19

用途:試料の低温保管など Purposes:Low temperature storage of samples, etc.
屋内用 Indoor use only
使用高度:高度2000m以下 Specification altitude: 2000m or less
使用湿度範囲:80%以下 Operating humidity range :80% or less.
汚染度:2 POLLUTION DEGREE:2

DC12V

48W(4A)

−40℃〜10℃

(周囲温度25℃)

−40℃〜10℃

(Ambient Temp.25℃) 

0℃〜35℃

25L

幅695×奥行き350×高さ460mm

W695×D350×H460mm  

16.5kg

DC電源コード(DC Power cord)…3m

使用電源  

Operating voltage

消費電力(約)  Power consumption(Approx.)

設定温度(約)

(空の状態)

Setting Temperature(Approx.)(The box is empty.)

使用温度範囲  Operating Temp. range

有効内容積  Usable capacity

製品寸法(約) Dimension(Approx.)

製品質量(約) Weight (Approx.)

コード  Cable

付属品  Accessaries

仕様

  

Specifications

運転を停止してから、電源プラグをはずしてください。                     

Switch the unit off using Power button and unplug.
庫内の貯蔵品を全部とりだし、庫内を清潔にして水分をよく拭きとっておきましょう。      
Remove any items being stored in the Cool box. Clean the inside of the Cool box and wipe 
off any moisture. 
フタはときどき開けて庫内の空気を入れかえてください。                 
庫内に市販の冷蔵庫脱臭剤を入れておかれると更によいでしょう。             
Open the lid occasionally to refresh the air in the Cool box.             
For improved effectiveness, place a commercially available deodorizer in the Cool box.

温度ロガーは中の電池を取り外し、本体部やセンサー部を軽く拭いて保管してください。

 For the temperature logger, remove the battery inside and wipe the main body and 

sensor part lightly before storing.

長期間ご使用にならないときは

 

Extended Disuse 

①ディープフリーザー / 

DEEP FREEZWER

②温度ロガー / 

Temperature Logger

マット(Mattress) …1、ACアダプター(AC adaptor)… 1、
DC電源コード(DC Power Cable)…1、内フタ(Inner Lid)…1、
取扱説明書(Instruction Manual)…1、温度ロガー(Temperature Logger)…1

●「温度ロガー(G-TAG 品番:GT002-T-DF 神栄テクノロジー株式会社製)」とビュワーアプリ
 「TH View」の仕様/使い方に関する詳細は、温度ロガーに同梱されてる取扱説明書に記載して
 おります。ご確認ください。
●お問い合わせ先は下記又は神栄テクノロジー株式会社 HPをご確認ください。

神栄テクノロジー株式会社

TEL 078 304 6795   FAX 078 302 1225
受付時間

月〜金 午前9

00〜午後5

00(祝日/休日を除く)

WEB : https://www.g-tag.jp E-mail : [email protected]
住所 兵庫県神戸市中央区港島南町6丁目5番2

18

SC-DF25WL

䚷䚷䚷䚷䚷䚷䚷䚷䚷䚷䚷䚷㼀㼃㻵㻺㻮㻵㻾㻰㻌㻯㻻㻾㻼㻻㻾㻭㼀㻵㻻㻺㻌㻯㼛㼚㼒㼕㼐㼑㼚㼠㼕㼍㼘㻌㻰㼛㼏㼡㼙㼑㼚㼠㻌㻺㼛㻚㼀㻮㻙㻜㻜㻜㻝㻟㻟㻝㻡㻌㻯㼛㼚㼒㼕㼞㼙㼑㼐㻌㼎㼥㻌㻶㼡㼚㻌㻷㼛㼙㼍㼐㼍㻌㻞㻜㻞㻜㻛㻝㻞㻛㻞㻟㻚

Summary of Contents for SC-DF25WL

Page 1: ...e this instruction manual Instruction Manual DC12V AC AC100V SC DF25WL Table of Contents Safety Precautions 1 Preparation 2 How to use the freezer 3 How to use the logger 4 How to use the viewer 7 8 S...

Page 2: ...ms on the lid Heavy item may fall causing injury Use caution when transporting Unit becomes after storing items inside AC Do not use any AC adapter other than the dedicated one May cause malfunction A...

Page 3: ...pen and close the lid gently to avoid getting your hand caught Prohibited Prohibited Prohibited Prohibited Prohibited Warning Caution Caution Condensation will form on the product during operation Qui...

Page 4: ...of the current capacity The lter cannot be completely removed Clean after pulling open for access After cleaning the lter return it to its original postion to avoid malfunction Be sure to connect to...

Page 5: ...e unit DC Be sure to disconnect the DC power cable when the engine has been switched o Caution DC12V DC24V DC12V Only Can not be used in DC24V 250Vac 8A Time lag 6 35 30 Use a fuse with the speci ed s...

Page 6: ...Note The main unit must not be put in the freezer Mattress Instruction Manual Calibration certi cate Velcro Loop Battery coin shape CR2450X Instruction Manual Accessories DC DC power cable Inner Lid...

Page 7: ...ture SET indicator Set temperature display Error Error indicator 1 Temperature pre set buttonfor 40 20 and 4 Temperature control button UP DOWN by 1 Parts Name and Functionand Handle Lid Lid release A...

Page 8: ...alling batteries TH View Register the temperature logger in the viewer TH View 7 Start Stop log collection of temperature logger Start logging Stop logging Save logs and send reports 20 This is the ba...

Page 9: ...freezer 2 DC Attach the cord stopper to the DC plug 3 AC AC DC Insert the AC plug of AC adapter or the power plug of DC power cord AC For using AC adapter AC Insert the cord set into the adapter body...

Page 10: ...ling Caution Do not put the temperature logger in the freezer cabinet It will be the cause of the failure Basic Procedure 3 3 Check the temperature inside the refrigerator with a temperature logger Ba...

Page 11: ...also unplug the AC plug of the AC adapter or the power plug of the DC power cord 5 After use Overloading interferes with the ow of cold air 1cm Leave adequate space A When using a preset Press the tem...

Page 12: ...iewer TH View 1 Remove the battery lid on the back of the temperature logger by turning it counterclockwise with a coin or the like 2 CR2450 CR2450 Insert the attached coin shaped lithium battery CR24...

Page 13: ...onger to blink BLE lamp 4 BLE TH View G TAG While the BLE lamp is blinking press the New G TAG added display at the bottom of the TH View screen to detect the target temperature logger If the detectio...

Page 14: ...e right side of the measurement start button to save the log After saving return to 4 and start measurement 3 TH View On the TH View screen select the linked logger to switch to the details screen Sto...

Page 15: ...you press the log acquisition button the log will be downloaded from the temperature logger to TH View 5 After downloading click the Save button in the center of the screen to display the Save log li...

Page 16: ...he main unit or drips put of the Cool box Put water sensitive items in containers or plastic bags before refrigeration Condensation is a natural phenomenon and is not a sign of malfunction Never wipe...

Page 17: ...Inner Lid is not set Set the Inner Lid Remove some of the items in the refrigerator Please contact your local dealer The unit is exposed to direct sunlight or there is a gas burner or stove nearby Cha...

Page 18: ...epair fee consists of the technical fee and the parts fee Technical Fee This is the charge for repairing a broken product and replacing parts Parts Fee It is the price of the parts used for repair Abo...

Page 19: ...o using Power button and unplug Remove any items being stored in the Cool box Clean the inside of the Cool box and wipe o any moisture Open the lid occasionally to refresh the air in the Cool box For...

Page 20: ...2 TB 00012930 1 2 ON OFF OFF Power OFF LED...

Reviews: