DRAIN PUMP REMOVAL INSTRUCTIONS
18
Drain Pump Removal Instructions:
1. Unplug ice machine from the electrical supply and re-
move the rear access cover from the ice machine. (See
page 6 for instructions).
2. Unscrew the leveling leg in the back corner until the
end of the threaded portion is flush with the threaded
nut insert in the base. (see Figure 25 ).
3. Unscrew the 4 hose clamps and remove the 3 hoses
from the front of the drain pump. (See Figure 25).
4. Rotate the drain pump and remove from the ice ma-
chine, (See Figure 26). It may be necessary to discon-
nect the ground wire connection in the back flange of
the cabinet. (See Figure 25).
5. Disconnect the ice machine power cord from the drain
pump (See Figure 27).
6. To drain water from the pump follow step 13 to 16 on
page 16.
7. Installation of drain pump is reverse of this procedure.
To Restart the Ice Machine
1. With the rocker switch in the OFF position, plug the ice
machine into an electrical outlet.
2. Reconnect and/or turn on the water supply line.
3. Reconnect drain tubing if removed.
4. Turn the rocker switch to the ON position.
5.
Check the water inlet, drain lines, and fittings for any
water leaks.
6. Check drain pump (if equipped) operation by pouring
approximately two (2) quarts of water into the ice stor-
age bin. The drain pump should activate and dis-
charge water (refer to Drain Pump on page 6). Check
for water leaks at all hose connections.
14. Remove the top clamp from the vent tube, for easier
access for the air hose.
15. Apply air pressure (approximately 10 psi) to the end of
the vent tube which will purge the remainder of the
water from the drain pump and the drain line. (See
Figure 24).
16. Reinstall the vent tube and clamp to the back of the ice
machine and remove the winterization plug from the ice
bin and save it for future use.
Figure 24
Vent
tube
Remove
clamp
screw
Drain
line