3
INSTALLATION OF BREAKFAST CLUB
Safe and satisfactory operation of the Breakfast Club depends upon its proper installation. The
installation, adjustments and service of the Breakfast Club must be performed only by a qualified installer
and service technician. This is necessary to ensure proper operation and also to prevent accidents.
Location
When determining a suitable location take into account concerns such as exposure to wind, proximity
to traffic paths and keeping any gas supply lines as short as possible. Locate the Breakfast Club only in a
well-ventilated area. For free standing configurations allow 12” from the sides and rear to combustible
construction while in operation.
Warning
This appliance should not be located closer than 12” to any adjacent combustible surface or under
any overhead unprotected combustible construction.
The appliance is design-certified for use outdoors only and is not intended to be installed in or on
recreational vehicles and/or boats. This appliance must be on a level, stable surface in an area clear of
combustible material. An asphalt surface may not be acceptable for this purpose.
Location of Breakfast Club
Proper location and use is essential to ensure safe and continued trouble-free operation. Any
alterations made to the appliance will void the product’s warranty.
The Breakfast Club must be located outdoors only. As with any gas appliance, harmful carbon
monoxide is produced during the combustion process that should not be allowed to accumulate in a confined
space. Also, since hot air rises above the Breakfast Club while in operation, covered locations should be
avoided. Do not locate the Breakfast Club where an overhang or awning may cover it.
Minimum clearances to combustible surfaces must be maintained when operating this appliance, and
are as follows:
The determination of whether a location is combustible or non-combustible construction is made by
the local fire marshal, building inspector or the local safety authority having jurisdiction
.
Wall
Clearance
Sides
12”
Back
12”