LIQUID PROPANE CONNECTION 

Notice 

 

All gas installations, conversions, and/or adjustments must be performed by an authorized service agent.  

 
Notice 

 

If your Breakfast Club is for Liquid Propane application, a factory supplied L.P regulator is set for 

11” WC and is for use with L.P. gas only.  The factory-supplied regulator and hose must be used with a 20 
lb. L.P. cylinder.  For plumb-in installation (system L.P. installation), the regulator must be changed and a 
main gas shutoff valve must be installed.  Contact your Twin Eagles dealer for a system L.P. regulator.  
 
 
 
 
 
 
 
 
 
 
 
 
 

NOTE

: An enclosure for a propane gas cylinder shall be vented by openings on the level of the cylinder 

valve and at floor level.  The effectiveness of the opening(s) for purposes of ventilation shall be determined 
with the propane gas supply cylinder in place.  This shall be accomplished by one of the following:  
 

a.

 

One side of the enclosure shall be completely open; or,  

 

b.

 

For an enclosure having four sides, a top and a bottom:  

 

1.

 

At least two ventilation openings at cylinder valve level shall be provided in the sidewall, equally 
sized, spaced at 180 degrees (3.14 rad), and unobstructed.  Each opening shall have a total free 
area of not less than ½ square inch per pound (7.1cm²/kg) of stored fuel capacity and not less 
than a total free area of 10 square inches (64 cm²).  

 

2.

 

Ventilation opening(s) shall be provided at floor level and shall have total free area of not less 
than ½ square inch per pound (7.1 cm²/kg) of stored fuel capacity and not less than a total free 
area of 10 square inches (64.5 cm²).  If ventilation openings shall be at floor level and are in a 
sidewall, there shall be at least two openings. The bottom of the openings shall be at floor level 
and the upper edge no more than 5 inches (127 mm) above the floor.  The openings shall be 
equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.  

 

c.

 

Every opening shall have minimum dimensions so as to permit the entrance of 1/8 inch (3.2 mm) 
diameter rod. 

 
 
 
 
 

! WARNING ! 

The gas supply hose should be inspected prior to each use.  Do not use a gas hose that has abrasions, cuts, 

or excessive wear. 

 

The gas supply must be turned off at the LP Gas supply cylinder and the LP Gas supply cylinder 

must be disconnected from the regulator when this outdoor cooking gas appliance is not in use. 

 

When your Breakfast Club is stored indoors, remove and store the LP Gas cylinder outdoors in a 

protected, cool, and dry location out of reach of children.  The cylinder should not be stored in a building, 

garage, or any other enclosed area 

Summary of Contents for BREAKFAST CLUB TEBC30-C

Page 1: ...P N 19238A 01 17 BREAKFAST CLUB INSTALLATION USE AND CARE MANUAL MODEL TEBC30 C...

Page 2: ...n Keep this manual in a safe place for future reference Thank you and welcome TWIN EAGLES _____________________________________________________________________________ FOR YOUR RECORDS Please record t...

Page 3: ...is or any other appliance A V E R T I S S E M E N T 1 Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables dans le voisinage de l appareil ni de tout autre appareil...

Page 4: ...lammable vapors and liquids 7 DO NOT obstruct the flow of combustion and ventilation air to this appliance Keep the ventilation openings of the cylinder enclosure free and clear from debris 8 Check al...

Page 5: ...NNECTION LEAK TEST 7 OPERATION 8 Lighting Instructions 8 Manual Lighting Instructions 9 Extinguishing the Burner Flame Replacing the Battery 9 CLEANING MAINTENANCE 9 General Overview 9 Stainless Steel...

Page 6: ...W and 8A Propane or LP If your Breakfast Club is factory built for LP the regulator supplied is set to 11 water column and is for use with LP gas only The factory supplied regulator and hose must be u...

Page 7: ...REQUIREMENT The LP gas supply cylinder must be constructed and marked in accordance with the Specifications for LP gas Cylinders of the U S Department of Transportation D O T or the National Standard...

Page 8: ...d to be installed in or on recreational vehicles and or boats This appliance must be on a level stable surface in an area clear of combustible material An asphalt surface may not be acceptable for thi...

Page 9: ...malfunctions or has been damaged in any manner Contact the manufacturer for repair 4 Do not let cord hang over the edge or touch hot surfaces 5 Do not us an outdoor cooking gas appliance for purposes...

Page 10: ...s connection in two locations The openings are indicated by the square dashed cut outs in the diagram above All dimensions shown are for planning purposes only Twin Eagles Inc reserves the right to ch...

Page 11: ...he pin away from the brass cap the regulator is set for system LP application To convert to natural gas remove the plastic conversion pin and invert and replace it back in a manner such that the disc...

Page 12: ...stem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psi 3 5 kPa A typical natural gas installati...

Page 13: ...ve a total free area of not less than square inch per pound 7 1cm kg of stored fuel capacity and not less than a total free area of 10 square inches 64 cm 2 Ventilation opening s shall be provided at...

Page 14: ...aks using a soapy water solution 6 See figure above for a typical LP gas hook up 7 To disconnect after use turn the burner knob to the OFF position Close the Cylinder Valve by turning the Hand Wheel c...

Page 15: ...e and regulator must be used Use only replacement regulator and hose assemblies specified by Twin Eagles LEAK TEST 1 Prepare a leak testing solution of sudsy water by mixing in a spray bottle with hal...

Page 16: ...ning and maintenance page of this manual Lighting Instructions Top Burners 1 Remove the covers from the Top Burners 2 Ensure the gas supply cylinder valve is closed and the burner knobs are set to the...

Page 17: ...before turning the knob 5 If ignition does not take place within 4 seconds turn the burner knob to the off position leave the cover off and wait 5 minutes to repeat lighting procedure 6 CAUTION Do no...

Page 18: ...ming pool hot tub or water feature with exposure to corrosive pool chemicals and or chlorinated water Areas where muriatic acid hydrochloric acid or other corrosive cleaning solutions are used to clea...

Page 19: ...tray after every use to avoid any possibility of a grease fire Allow the tray and its contents to cool before cleaning The grease tray is located in front of the griddle plate assembly Lift the tray...

Page 20: ...to operate Inspect the burners once a year or if the Breakfast Club has not been used for more than a month or if any of the following conditions occur 1 The smell of gas in conjunction with the burne...

Page 21: ...16 EXPLODED VIEW...

Page 22: ...tch Illuminated 19mm Blue 1 24 S15312 Thermostat 1 25 S16113 Pilot Light Red 1 26 S13203 Twin Eagles Emblem 1 27 S12710 Manifold 1 28 S12603 Elbow Mixer 375cc 1 29 S15149YSB Valve Burner TEBC 2 30 S26...

Page 23: ...18 WIRING DIAGRAM...

Page 24: ...es discoloration surface scratches weather and atmospheric related staining and minor surface rust and oxidation which are normal conditions and are to be expected with any outdoor product This warran...

Page 25: ...esgrills com Please provide Model number Serial Number Date of Purchase A description of the problem WARRANTY REGISTRATION Customer Name Model Address Serial City State Date Purchased Zip Dealer s Nam...

Page 26: ...21 Customer Service ATTN Warranty Department 13259 East 166th Street Cerritos Ca 90703 Fax No 562 802 3391...

Reviews: