Checking Continuity
3.4
Checking Continuity
The input short circuit is detected and informed via a buzzer.
WARNING
Before measuring, be sure to turn off the power to
the measurement circuit. Otherwise, electric shock
may occur or the instrument may be damaged.
1
1
2
2
For the DT4223
(The position of the rotary
switch varies depending on the
model.)
Detection
Threshold
Buzzer
Short circuit detection 25
Ω
±10
Ω
Sounds
(continuous buzzer sound)
Open detection
245
Ω
±10
Ω
Does not sound