background image

Thanking you for choosing to our product please read carefully the instructions in This manual installation instructions. 
The product is manufacturing "Made in Italy", made of timber northern origin and is identified by a special label that specifies: 
item code and its description, serial number, signature of quality control.
BEFORE ASSEMBLY
After unpacking, check that there are no damaged parts, missing or incorrect; in case occurs one of these cases, contact dealer. 
If you are missing any components NOT assemble the structure partially, to prevent damage or that can create any dangerous 
situations. Before assembly, check that the foundations are perfectly level to avoid problems of misalignment that affect the 
stability of the structure and consequent difficulty opening / closing doors and windows; in this respect it should implement a plan
concrete of 15-20 cm thick.
DURING ASSEMBLY
Before you tighten the lag bolts is recommended pre-drill the piece to be fixed with a wood drill bit with a diameter less than the 
diameter of the screw. Where in the assembly instructions is the image of the point you need to make a tapping hole of diameter 
indicated in order not to damage the workpiece.
SAFETY
It is recommended to carry out the work always adopting the personal protective equipment such as gloves and goggles and
handle with care tools and power tools, as well as pay special attention in the use of the scale during the phases of assembly. 
It is also recommended to keep children away from the installation area for the duration of the same.
MAINTENANCE
To prolong the life of wooden structures, it is necessary a correct and constant maintenance adapted especially to protect
by: weathering, UV, mold and mildew; To this purpose, it is advisable to impregnate the structure with impregnating waxed
external choosing the desired shade of the colors proposed. It is recommended to treat the elements of the structure on all 
sides for complete protection and lasting and repeat the maintenance once a year or any time before the treatment previous've 
lost shine and shades. Once installed in the structure, carry out checks on stability of the same. During the checks to verify the 
tightness of the nuts and tighten them if necessary.
WARRANTY
As required by law, the warranty on manufacturing defects has a duration of 2 years from the date of purchase, it is 
recommended Therefore, to keep the tax documents that certify the purchase. Warranty claims received after the expiry of the
itself, will NOT be accepted and in NO case Verrano reimbursed costs of labor, assembly and the like. NOT warranty defects 
resulting from: foundations not flat, errors in the assembly of the structure, lack of adequate maintenance, use of fasteners 
other than those supplied, natural disasters, violent weather, speed wind strength greater than or equal to 7 on the Beaufort scale.
TOLERANCE OF WOOD
Wood is a natural material and alive, so it is normal that each element is different, and therefore are allowed commonly accepted 
the following irregularities: nodes having a maximum diameter of 5 cm, loose knots closable in phase mounting, cracks at the 
ends of the boards that do not affect the width, not continuous cracks, cracks lower to 7 cm in length, deformations or bends 
that do not affect the assembly. In case, falling of the nodes, obturate with wood putty; remove any resin pockets with normal 
spatula.
COMPLAINTS
Any complaints should be reported to the store, making sure to communicate item code and tax documents related to the 
purchased product.
LIABILITY '
Alce s.r.l. responsible for any use and / or incorrect installation or improper use of the materials sold. All verifications Static 
and security must be controlled by a local technician as a function of: the place of installation; validity of the supports and the 
corresponding fasteners; extent of any attics; use of coverage as a function of wind or snow load of installation areas.

EN

pag. 3

Summary of Contents for ARBOR MANHATTAN 03420

Page 1: ......

Page 2: ...olori proposti Si raccomanda di trattare gli elementi della struttura su tutti i lati per una protezione completa e duratura e di ripetere la manutenzione una volta l anno o comunque prima che il trat...

Page 3: ...It is recommended to treat the elements of the structure on all sides for complete protection and lasting and repeat the maintenance once a year or any time before the treatment previous ve lost shine...

Page 4: ...Farben Es wird empfohlen die Elemente der Struktur von allen Seiten zu behandeln F r einen vollst ndigen Schutz und dauerhafte und wiederholen Sie den Wartungs einmal im Jahr oder jederzeit vor der Be...

Page 5: ...les l ments de la structure de toutes parts pour une protection compl te et durable et r p ter l entretien une fois par an ou tout moment avant le traitement Previous ve perdu l clat et les nuances U...

Page 6: ...nts devant tre d livr par A P r alisation de l uvre en conformit avec les r glements de construction actuelles qu il soit national r gional ou municipal To ensure the structure in every condition of o...

Page 7: ...lage la structure et la stocker dans un endroit sec et nivel Veillez galement couvrir avec une b che emballage fourni AVVERTENZA prima del montaggio scaricare la struttura e riporla in luogo livellato...

Page 8: ...4x40mm VD VC 10x200 10x300 VB 10x400 VA 8 x pag 8 7 A 1x 359 cm 2x B 380 cm 2x C 380 cm 4x D 4x E 246 cm 40 cm 10 03420 F G 24x 2x 8 x 8 x 8 x 8 mm 7 20...

Page 9: ...L1 L2 L1 L2 2x VA 4x 2x D B 90 90 pag 9 2x G 1 4x 4x...

Page 10: ...pag 10 340 cm 360 cm VA 2x C G 2 4x 4x...

Page 11: ...pag 11 3 VB G 8x 8x...

Page 12: ...90 VC 8x E 4x 8x pag 12 G 8 mm 4 8 mm 2cm...

Page 13: ...interposed in the joints above at the junction of the beams for prevent the entry meteoric water not included in the kit Wache Silizium geeignet f r in den obigen Verbindungen zwischen an der Verbindu...

Page 14: ...pag 14 03421 VE 4x50mm 2 3 4x H 178 cm 2x I 11mm VF 20 x 16 x 1...

Page 15: ...pag 15 4x H 4x 6 I 2x VF 20x 16x VE...

Page 16: ...03422 J 2x 358 cm 4 5 5 pag 16 4x 2 4x 1 353 cm L M 2 cm 160 cm 4x K 4 5 5 4x50mm VH VG 4 x 8x100mm 24 x 8 mm 13 1x 4x 4x N O P 4 4...

Page 17: ...4x K 16x VG pag 17 10 cm 7...

Page 18: ...J 2x L 4x VH 4 x 8 mm 0 5 cm 3 cm 3 cm 3 cm pag 18 8 8 mm...

Page 19: ...2x pag 19 9 4x M 1x P 4x N N...

Page 20: ...VG 4x 8x pag 20 10 5 cm 110 cm O...

Page 21: ...pag 21 11...

Page 22: ...pag 22 26046 8x 10 mm 5 cm 5 cm M10x120mm VI 16 x 16 x 16 x VJ VK 17 10 mm Q...