TWECO 201TS
TROUBLESHOOTING
Troubleshooting 6-8 Manual 0-5150
6.07 DC Bus Voltage Check
!
Warning: Measure DC voltage reading with multimeter before inspection. Set multimeter to DC volt-
age mode.
!
Read and follow safety information in Section 6.02 before proceeding.
1. DC Positive
2. DC Negative
Check and make sure input capacitors are discharged and voltage is near 0 VDC. When powered up voltage
should read 385 VDC.
2
1
Art # A-10162