4.03 Stick (SMAW) Setup
200A
Set Welding Current
as specified by the
Electrode Manufacturer.
Set Process Selection
Switch to STICK.
Set ARC Force
Positive Output
Terminal
(Dinse™ 50)
Negative Output
Terminal
(Dinse™ 50)
Art#: A-09784
Figure 4-2: Setup for STICK (SMAW) Welding
STICK (SMAW) Mode Sequence of Operation
CAUTION
Before any welding is to begin, be sure to wear all appropriate and recommended safety equipment.
1. Switch the ON/OFF Switch (located on the rear panel) to OFF.
2. Connect the work lead to the negative output terminal, and the electrode holder cable to the positive output
terminal. It is essential that the male plug is inserted and turned fully clockwise until connector locks in place
to achieve reliable electrical connection.
NOTE
This set up is known as DC Electrode Positive or reverse polarity. Please consult with the stick electrode manufacturer for
specific polarity recommendations.
3. Connect the work clamp to your workpiece.
4. Plug the power cable into the appropriate outlet, and turn the switch to the “ON” position. The power L.E.D
light should illuminate.
5. Set the “Process Selection Switch” to STICK.
Summary of Contents for ArcMaster 201 TS
Page 6: ...TABLE OF CONTENTS This Page Intentionally Blank...
Page 18: ...TWECO 201TS INTRODUCTION introduction 2 2 Manual 0 5150 This Page Intentionally Blank...
Page 48: ...TWECO 201TS TROUBLESHOOTING Troubleshooting 6 12 Manual 0 5150 Art A 09895_AB...
Page 50: ...TWECO 201TS TROUBLESHOOTING Troubleshooting 6 14 Manual 0 5150 This Page Intentionally Blank...
Page 61: ...DISASSEMBLY PROCEDURE TWECO 201TS Manual 0 5150 7 11 Disassembly Procedure 6 2 Art A 10179...
Page 71: ...Manual 0 5150 8 9 Assembly Procedures ASSEMBLY PROCEDURE TWECO 201TS 1 Art A 10160...
Page 78: ...TWECO 201TS ACCESSORIES Accessories 10 2 Manual 0 5150 This Page Intentionally Blank...