6. Measurement of In Rush Resistor R1.
Set multimeter to Ohm mode. Ohm reading should be 4Ω±5%.
Positive Probe
Negative Probe
Measure Point 17
Measure Point 18
If reading is not 4ohms within ±5%, replace Resistor R1.
7. Power Switch S1 Continuity Check
3
Art # A-10265
1
2
4
!
Read and follow safety information in Section 6.02 before proceeding.
1. ON/OFF switch. Power Switch. Multimerer set to Measure ohms (
Ω).
Power Switch Testing
Multimeter Lead Placement
Impedance
Switch ON
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
0 to 1Ω
Switch ON
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
1 to 1Ω
Switch OFF
Positive meter lead to testpoint 23
Negative meter lead to testpoint 24
>1kΩ
Switch OFF
Positive meter lead to testpoint 25
Negative meter lead to testpoint 26
>1kΩ