05 MENU OPERATIONS
13
FHD Hight Bright Field Monitor
[2] COLOR
• EETF
(Electrical-Electrical Transfer Function)
- Used to display the HDR image(without clipping)
within the actual luminance range (black level
and peak luminance) that the monitor can
express. In the ON mode, the HDR image is
converted within the range of set peak luminance
and black level. In the OFF mode, the video
signal outside of the set range is clipped.
- Available modes are OFF and ON.
- Available only when the EOTF is set to PQ or
SLOG3.
*Activates only in [STANDARD - USER 1/2/3] mode.
• HLG SG (HLG System Gamma)
- Used to set the System Gamma of HLG mode.
- In the ON mode, the value of the System
Gamma changes automatically according to the
previously set peak luminance. When it is OFF,
the value is set to default value of 1.2.
* Activates only when the EOTF is set to HLG, and
STANDARD is set to USER 1/2/3.
• SG (System Gamma)
- The System Gamma of HLG is automatically
calculated and displayed according to the set
[PEAK LUMINANCE].
- Activates only when the EOTF is set to HLG and
the HLG SG is ON.
• CAM LUT
(Camera LUT)
- Used to change the Camera LUT.
- Available LUTs are LOG-C, C-LOG, S-LOG1,
S-LOG2, S-LOG3, REDGAMMA3, REDGAMMA4.
* Activates only when STANDARD is set to USER
1/2/3, and EOTF is set to 2.2, 2.4, 2.6.
• CAM LUT THROUG
(Camera LUT Through)
- Apply the currently applied LUT to Through Out.
COLOR
같이
F-7HS
STANDARD
VIDEO RANGE
PEAK LUMINANCE
BLACK LEVEL
COLOR GAMUT
COLOR TEMP
EOTF
LOCAL DIMMING
EETF
HLG SG
S . G
CAM LUT
CAM LUT THROUG
HD
LIMITED109
100
0.001
BT709
6500K
2.4
OFF
OFF
OFF
OFF
OFF
PAGE (1/2)
PEAK LUMINANCE
SG (System Gamma)
100
0.78
200
0.91
300
0.98
400
1.03
500
1.07
600
1.11
700
1.13
800
1.16
900
1.18
1000
1.20
2000
1.33
3000
1.40
4000
1.45
5000
1.49
6000
1.53
7000
1.55
8000
1.58
9000
1.60
10000
1.62