93
F
04
00
41
01
02
000001 ?? CR
F
44
00
42
01
02
000001 8A CR
Set 1A Shrink to 110 – invalid max for shrink is 100
F
04
00
41
00
87
00006E ?? CR
F
44
00
41
00
87
000064 70 CR
Read 1C Zoom level – invalid as window C does not
exist
F
84
00
43
00
86
-
?? CR
F
04
00
43
00
86
000000 CD CR
Read 1B Zoom level
Zoom = 100
F
84
00
42
00
86
-
?? CR
F
44
00
42
00
86
000064 70 CR
Set baud to 9600
Reply is at 9600 baud
F
04
00
42
00
AB
000000 F0 CR
F
44
00
42
00
AB
000000 30 CR
Set 1A Zoom = 300
F
04
00
42
00
86
00012C F7 CR
F
44
00
42
00
86
00012C 37 CR
Set 1A Shrink to 50
F
04
00
42
00
87
000032 FE CR
F
44
00
42
00
87
000032 3E CR
Set 1A Shrink H Posn to 0
F
04
00
42
00
DA
000000 1F CR
F
44
00
42
00
DA
000000 5F CR
Set 1A Shrink V Posn to 100
F
04
00
42
00
DB
000064 84 CR
F
44
00
42
00
DB
000064 C4 CR
11.5
Reading and writing macros
Depending on the unit connected there can be up to 7 macros stored in the
unit. These macros can be programmed to perform a specific task, for
example enable PIP mode, Position pip window at H=0, V=0, Zoom in to
120%.
The WIN and OUT bytes are not used for macro reading or writing and should
be set to WIN=1A and OUT = 0
The CHA byte indicates the macro we are programming / reading / running.
Macro 1 to 5 are CHA 0..4, CHA=5 is restore, CHA 6..7 are Macros 6..7.
Macro Restore (CHA=5) is read only, the units restore state is set by sending
the Store command (0C8).
Menu text
CHA FUNC
(Hex)
Range of adjustment (decimal)
Macro
Run macro
0..7 F1
0..1 = Run, Erase macro
Number of items within
macro
0..7 F4
Read Only
Function to adjust
0..7 F2
0..4095
Value
0..7 F3
Value for Function