607.32.09.00
Last updated 2022/03/22
- 3 -
GB
Installation
–
scope of delivery
–
Assembly
Item Designation
Item
Designation
1
Housing with valve taper
H
Height adjustment
2
Sealing hood
Factory setting H=46 mm
3
Adjusting screw with markings
(74 mm for DN 40 and DN 50)
4
Lock washer for height restriction
equivalent to 1.5 m anti-syphon
protection height
5
Threaded pin
Technical data
Designation/type
tubra
®
angle check valve
Nominal size
DN 25
DN 32
DN 40
DN 50
Anti-siphoning valves
1.5
–
3 m adjustable under system pressure
Opening pressure relief valve
2 bar
Max. operating pressure
10 bar
Max. operating temperature
95 °C
Connections
Inlet T1 IT
T1¼ IT
T1½ IT
T2 IT
Outlet T1 IT
T1¼ IT
T1½ IT
T2 IT
Approved media
Lubricants, oil, fuels, petrol, diesel, heating oil,
kerosene, biodiesel, rapeseed oil
Permissible temperature range for use
For biodiesel and rapeseed oil < 25 °C, for all
other substances < 40 °C
Materials
Fitting
CW614N (2.0401)
CC745S-GM (2.0340.02)
Pressure spring
Stainless-steel
Flat seal
NBR yellow
O-ring
FPM (Viton)
H
2
1
5
3
3.0 m
2.5 m
2.0 m
1.5 m anti-syphon
protection height
4
Summary of Contents for tubra DN 25
Page 1: ...D tubra Eckr ckschlagventil DN 25 DN 50 Montage und Bedienungsanleitung...
Page 8: ...GB tubra angle check valve DN 25 DN 50 Assembly and operating instructions...
Page 15: ...I Valvola di non ritorno angolare tubra DN 25 DN 50 Istruzioni di assemblaggio e d uso...
Page 22: ...FR Clapet anti retour en querre tubra DN 25 DN 50 Instructions de montage et de service...