8
04
Description
Manual 2008 Rev A p/n 2008
SPECIFICATIONS
MODEL
APPROXIMATE OIL CAPACITY
PORT SIZE
MAX
RPM
APPROXIMATE WEIGHT
VERTICAL
FLOW
HORIZONTAL
FLOW
VERTICAL
FLOW
HORIZONTAL
FLOW
9016
8.0 gal (30.3 L)* 5.0 gal (18.9 L)* 12 in. (305 mm)
2400
2000 lb
(907 kg)
2000 lb
(907 kg)
9020
8.0 gal (30.3 L)* 5.0 gal (18.9 L)* 12 in. (305 mm)
2400
2300 lb
(1043 kg)
2300 lb
(1043 kg)
9027
8.0 gal (30.3 L)* 5.0 gal (18.9 L)* 14 in. (356 mm)
2400
2850 lb
(1292 kg)
2850 lb
(1292 kg)
Table 4-1 – Specifications
* Integral Lube units require up to 2 additional gallons.
MODEL MAXIMUM RPM
MAXIMUM
PRESSURE
DIFFERENTIAL
MAXIMUM VACUUM
MAXIMUM
TEMPERATURE
RISE
MAWP
9016
2400
15 psi
(1,035 mbar)
15 inch-Hg
(508 mbar)
280°F (156°C)
35 psi
(2.4 bar)
9020
9027
Table 4-2 – Maximum Operating Limits
WARNING
!
The maximum pressure differential is based
on the difference between the inlet pressure
and the outlet pressure. The maximum
pressure differential shall not be exceeded.
Exceeding the maximum pressure differential
will cause serious damage to the equipment
and could cause bodily injury.
WARNING
!
The maximum allowable working pressure
(MAWP) is based on the absolute pressure of
the blower housing and is NOT the maximum
allowable pressure differential. Exceeding
the MAWP will cause serious damage to the
equipment and could cause bodily injury.
To permit continued satisfactory performance, a
blower must be operated within certain approved
limiting conditions. The manufacturer’s warranty
is, of course, also contingent on such operation.
Maximum limits for pressure, temperature, and
speed are specified in
Table 4-2
for various
blower sizes when operated under the standard
atmospheric conditions. Do not exceed any of
these limits.
Summary of Contents for PD Plus 9000 Series