36
08
Disassembly and Reassembly
Manual 2008 Rev A p/n 2008
Complete Free End Assembly
(Series 19/55/66/69/82/86)
32. Install oil pump drive shaft, oil slinger, and
secure with cap screws. Put sealer on the end
cover. Grease and install O-ring. Align oil pump
coupling with slot in drive shaft and install
plate. Secure with cap screws. If oil pump is
being replaced, install new O-ring.
33. Apply sealer to housing and install port fittings.
Install cooler, oil filter, and external oil lines on
the unit with lube system.
SPECIAL INSTRUCTIONS FOR
GEAR HEAD BLOWERS
1. On units furnished with gear head drives
(ratio), follow disassembly procedures up to
and including step 6
on page 31
. Then
remove the cover end plate cap screws and
nuts using jack screw holes provided, remove
the drive end cover and tap out the lip seal.
2. Remove the gear housing cap screws and
gear housing using jack screw holes.
3. The drive shaft gear and bearing assembly can
now be tapped free from the housing. Remove
retainer rings and press shaft from bearing and
gear.
4. Tap out mating gear assembly and
disassemble in the same manner.
5. Remove stub shaft cap screws and stub shaft.
6. Continue blower disassembly (
see Gear End
Disassembly (Series 64/66/67/69) on page
31
, step 11).
7. Use reverse order to reassemble.
Summary of Contents for PD Plus 9000 Series