TUTA S30 GSM POWER SOCKET USER MANUAL
Method
The
Master
user sends following SMS message in order to:
Enable over-temperature alarm:
#170#1#
(24)
Set limits of temperature:
#170#
MinTemp
#
MaxTemp
#
(25)
•
MinTemp
and
MaxTemp
: The values can be set within the range
of -10 to 50 centigrade degree.
Default
MinTemp
is 20 and
MaxTemp
is 30 centigrade degree.
Disable the alarm upon going beyond limits temperature:
#170#0#
(26)
Successful SMS reply
Temperature alert: function ON/OFF
Min Temp.:**
Max Temp.: **.
3.7.2 Temperature rapid-changing alarm
Description
A time period value and temperature changing value can be pre-set
onto the socket. In this case, if the surroundings temperature
change to the pre-set value within the pre-set time period, a SMS
alarm message will be auto-sent to master’s mobile phone.