BOLTS REQUIRED FOR MOUNTING
Standard Wall/Universal Bracket
2
12mm x 75mm coach bolts & flat washers
2
12mm x 75mm dyna-bolts
Rafter Bracket Set - FA 22/FA 42 Only 2
10mm x 75mm Hex bolts (fully threaded),
nuts & spring washers - brick fix
2
10mm x 40mm Hex bolts (fully threaded),
nuts & spring washers - wood fix
Fascia Bracket- FA 22/FA 42 Only
2
10mm x 75mm Hex bolts (fully threaded),
nuts & spring washers
FA 42, FA 44 & FA 46 - INSTALLATION OF CENTRE SUPPORT
The centre supports should be assembled over the sewing joints which are located closest to the
centre of the awning. Adjust the angle of the centre support so that the fabric does not touch its
lower or upper lip.
ALL - FABRIC
Fabric requirement at projection: arm proj 250mm excluding valance.
FA 48 - POSITION OF FABRIC ONTO ROLLER TUBE
The fabric should be positioned 40 mm from the edge of bushing on the roller side, to come straight
into the cassette.
FA 58 - POSITION OF FABRIC ONTO ROLLER TUBE
The fabric should be positioned 25 mm from the edge of bushing on the roller side, to come straight
into the cassette.
FA 22, FA 42, FA 44, FA 45 & FA 46 - HOOD
The hood brackets should be assembled 600mm from the end bracket. Max distance between hood
brackets 1500mm.
SPECIAL INSTRUCTION FOR AWNING WITH THREE FOLDING ARMS
The folding arm in the middle should not have any spring tension in the connection between the
folding arm and arm bracket. Remove the spring tension in the centre arm at the arm connection at
the square tube. Remove the pin that holds the Dyneema
®
-tape with a small flat-headed screwdriver.
FA 22
No of installation bracket per width and projection
Width (m)
≤3m
≤4m ≤5m
1.0m
2
2
2
1.5m
2
2
4
2.0m
2
4
4
2.5m
4
4
4
3.0m
4
4
4
FA 42, FA 44, FA 45, FA 46, FA 48 & FA 58
No of installation bracket per width and projection
Width (m) ≤4
≤5
≤6
≤7
1,6 m
2
2
4
6
2,0 m
2
2
4
6
2,5 m
2
4
4
6
3,0 m
4
4
4
6
3,5 m
4
4
5
6
4,0 m
4
5
5
/
The awning width is defined as the total horizontal length of the awning excluding hood.
The arm brackets should be assembled 1/6 of the total width, from the end bracket, when the combination
of projection and width allows.
FABRICATION GUIDELINES
projection
projection