Turnils FA 22 Installation Manual Download Page 9

INSTALLATION - OPERATION - CLEANING — FA SERIES

 FOLDING ARM AWNING

9

BOLTS REQUIRED FOR MOUNTING

 

 Standard Wall/Universal Bracket 

  2 

12mm x 75mm coach bolts & flat washers 

   

 

  2 

12mm x 75mm dyna-bolts

 
 

 Rafter Bracket Set - FA 22/FA 42 Only   2 

10mm x 75mm Hex bolts (fully threaded),    

 

   

 

   

nuts & spring washers - brick fix 

   

 

  2 

10mm x 40mm Hex bolts (fully threaded),    

 

   

 

   

nuts & spring washers - wood fix

   
 

 Fascia Bracket- FA 22/FA 42 Only 

  2 

10mm x 75mm Hex bolts (fully threaded),    

 

   

 

   

nuts & spring washers

FA 42, FA 44 & FA 46 - INSTALLATION OF CENTRE SUPPORT

The centre supports should be assembled over the sewing joints which are located closest to the 

centre of the awning. Adjust the angle of the centre support so that the fabric does not touch its 

lower or upper lip.

ALL - FABRIC

Fabric requirement at projection: arm proj 250mm excluding valance.

FA 48 - POSITION OF FABRIC ONTO ROLLER TUBE

The fabric should be positioned 40 mm from the edge of bushing on the roller side, to come straight 

into the cassette.

FA 58 - POSITION OF FABRIC ONTO ROLLER TUBE

The fabric should be positioned 25 mm from the edge of bushing on the roller side, to come straight 

into the cassette.

FA 22, FA 42, FA 44, FA 45 & FA 46 - HOOD

The hood brackets should be assembled 600mm from the end bracket. Max distance between hood 

brackets 1500mm.

SPECIAL INSTRUCTION FOR AWNING WITH THREE FOLDING ARMS

The folding arm in the middle should not have any spring tension in the connection between the 

folding arm and arm bracket. Remove the spring tension in the centre arm at the arm connection at 

the square tube. Remove the pin that holds the Dyneema

®

-tape with a small flat-headed screwdriver.

FA 22

No of installation bracket per width and projection
 

Width (m)  

≤3m  

≤4m   ≤5m

 

1.0m  

  2  

  2  

  2

 

1.5m  

  2  

  2  

  4

 

2.0m  

  2  

  4  

  4

 

2.5m  

  4  

  4  

  4

 

3.0m  

  4  

  4  

  4

FA 42, FA 44, FA 45, FA 46, FA 48 & FA 58

No of installation bracket per width and projection
 

Width (m)   ≤4  

≤5  

≤6  

≤7

 

1,6 m  

2  

2  

4  

6

 

2,0 m  

2  

2  

4  

6

 

2,5 m 

2  

4  

4  

6

 

3,0 m 

4  

4  

4  

6

 

3,5 m 

4  

4  

5  

6

 

4,0 m 

4  

5  

5  

/

The awning width is defined as the total horizontal length of the awning excluding hood.

The arm brackets should be assembled 1/6 of the total width, from the end bracket, when the combination 

of projection and width allows.

FABRICATION GUIDELINES

projection

projection

Summary of Contents for FA 22

Page 1: ...INSTALLATION MANUAL FA SERIES FOLDING ARM AWNINGS INSTALLATION OPERATION CLEANING...

Page 2: ......

Page 3: ...c FA 42 SIROCCO Design FA 44 SIROCCO Cross Over FA 45 SIROCCO Fabric Beam FA 46 SIROCCO Semi Cassette FA 48 VIENTO Semi Cassette FA 58 Hunter Douglas Limited does not warrant the accuracy contained in...

Page 4: ...eries Vikarmsmarkis Folding arm awning 21 1 2016 Article No Description Note Stand pack Drive bushing 85 mm Polyamide for roller tube 74 8560 70 Drivbussning Polyamid f r valsr r 74 8560 70 Includes b...

Page 5: ...ost versions be provided with a hood profile of extruded aluminium and with aluminium hood side covers and hood bracket in extruded aluminium Joining piece in stainless steel PROFILES The front tube a...

Page 6: ...close to the arm s attachment on the supporting tube as possible Mark out and drill the holes for these brackets NOTE the wave line Mount the brackets using the requisite plugs and screws Stretch a p...

Page 7: ...awning Nordic Light FA20 Installation Operation Cleaning 3 Installing the roof Mount the roof brackets to the roof using a bracket at each outer end of the roof The remaining brackets are mounted at...

Page 8: ...stributed evenly ver the awning roof crew on the nuts loosely so that he roof can be adjusted when it is n place Mount the roof to the square tube nd tighten the screws hen move the roof bracket ownwa...

Page 9: ...R TUBE The fabric should be positioned 25 mm from the edge of bushing on the roller side to come straight into the cassette FA 22 FA 42 FA 44 FA 45 FA 46 HOOD The hood brackets should be assembled 600...

Page 10: ...where it will be exposed to maximum wind effect NOTE It is possible to connect one 1 single wind sensor to several controllers please contact us But you cannot connect several wind sensors to one 1 si...

Page 11: ...1 2015 4 Nordic Light FA20 Installation Operation Cleaning 2 Adjustment of projection angle The awning s projection angle is adjusted with the stop screw and the screw located in the arm holder Crank...

Page 12: ...w 2 is not stressed NOTE There may be a bang when the arm is lifted and the conical washer loosens Adjust the stop screw 2 so that the arm has the desired height position The recommended minimum incli...

Page 13: ...replaced in order for the awning to maintain its finish and function WARNING ALWAYS ALLOW A PROFESSIONAL TO ADJUST THE FOLDING ARMS An awning has very powerful springs inside the arm s aluminium profi...

Page 14: ...INSTALLATION OPERATION CLEANING FA SERIES FOLDING ARM AWNING 14 NOTES...

Page 15: ...INSTALLATION OPERATION CLEANING FA SERIES FOLDING ARM AWNING 15...

Page 16: ......

Reviews: