![Turnils FA 22 Installation Manual Download Page 10](http://html1.mh-extra.com/html/turnils/fa-22/fa-22_installation-manual_1182167010.webp)
INSTALLATION - OPERATION - CLEANING — FA SERIES
FOLDING ARM AWNING
10
MOTORISED AWNINGS
The limit switches should be adjusted to allow the awning to reach its maximum extension with the cover held
taut, and to retract fully without straining the mechanism.
Fix the wind sensor to its bracket in a vertical position and install it in an exposed position, as close as possible
to the awning. When using a wind sensor with several awnings/screens, install the sensor in a place where it
will be exposed to maximum wind effect.
NOTE:
It is possible to connect one (1) single wind sensor to several controllers (please contact us). But you cannot
connect several wind sensors to one (1) single controller.
Fix the sun sensor to its bracket in a vertical position and install it with the sensor facing the sun.
NOTE:
Use coupling device module when connecting several sun sensors to one (1) single controller. Ask for specific
wiring diagram.
The sun control can most conveniently be checked under sunny conditions by alternately exposing the sensor
to the sunlight and shading it. The wind control can be checked by blowing vigorously on the anemometer
paddles.