The processor detects voltage of one cell is too low.
The 4th cell was damaged. The value of voltage may be zero if
disconnection occurs.
The processor monitors voltage of each cell when the battery packs are during its storage
and discharging process. If voltage of any cell is abnormal, MEGA 400W×2 will show
error message and terminate the program forcibly. So if there is battery damage or
disconnection, you can see the error message and press
Inc
to know which cell is
damaged.
Voltage balancing and monitoring in the discharge process
DEC
-
Batt type
Stop
Elapsed
time
INC
+
DEC
Start
Enter
-
INC
+
Charged
capacity
Battery
type
Charge
current
Battery
voltage
This program is for charging of NiCd/NiMH batteries
associated with R/C models applications. You can press
Start/Enter
key to make it blink and then
Inc
or
Dec
to
change the parameter value. Press START/ENTER key to
store the value.
This program charge the battery using the current you set up. In the auto state,
you should set up the upper limit of the charge current to avoid damage by excessive
feeding current. Some batteries of low resistance and capacity can lead to higher current
in the auto charging mode. But in the manual mode, it will charge with the current you set.
You can make it blink in the current field and press
Inc
and
Dec
simultaneously to swap
between Auto and Manual Mode. NOTE: Allowable fast charge current: 1C-2C
The screen shows the real-time status. Press
Batt
Type/Stop
key to end the program. The sound will emitted to indicates
the end of program.
Charging NiCd/NiMH battery in the charge mode
'> 3 seconds '
CHARGING NICD/NIMH BATTERY IN THE CHARGE MODE