Intesis
Home
®
IS-IR-WIFI-1
User Manual r1.3 eng
© Intesis Software S.L. - All rights reserved
This information is subject to change without notice
IntesisHome
®
is a registered trademark
of Intesis Software SL
URL
Contact
http://www.intesishome.com
http://www.intesishome.com/contact
23 / 25
The anti-frost function includes also some protections such as:
· Automatic disabling if the AC unit is turned On manually.
· Keeps working even if Wi-Fi connection is lost.
· When operating, it re-sends the command to be applied each 10 minutes.
· When the anti-frost functions turns the AC unit On this will:
·First sends
On
-
Heat
-
SetPoint
(the one configured)
-
FanSpeed
(MID)
· After 2 seconds it will send
On
-
Heat
-
SetPoint
(the one configured)
-
FanSpeed
(HIGH)
13 LED status summary
According to the different stages where the device can work in, please find below the LED
status summary for your guidance.
13.1 LED status during Wi-Fi configuration
LED Color (s)
Behavior
Description
Blue
Blinking
Performing WPS connection (up to 2 min)
Magenta
Blink
WPS connection error
White
Blinking
Identifying IntesisHome Device
Green
Steady
Not configured
Green
Blinking
Checking device configuration parameter values(up to 2 min)
IMPORTANT:
Before changing the
protection temperature
below 16ºC, please check if your
indoor unit could work at indoor temperatures below 16º or check with the technical
department of the AC manufacturer.
IntesisHome will be not responsible of any damage
in the AC unit.
!
Time
Ambient Temperature
hysteresis (2ºC)
protection temperature (15ºC)
Indoor unit is OFF & anti-frost protection is enabled
Then, the IntesisHome device sends: ON, Heat, Set Point & Fan Speed High
Indoor temperature is over
protection tempe hysteresis
Then, the IntesisHome device sends: OFF