About this manual

This manual describes the setup, the functions and use of the product and helps you to operate 

the product for its intended use. Read these instructions carefully prior to using the product. 

This will prevent the risk of personal injury and damage to property. Keep these instructions 

safe during the service life of the product. If the product is passed on, pass on these instructions 

as well.

1.1 

Target groups

This document is written for specially trained personnel, and must be read carefully by anyone 

who is charged with the mounting, commissioning, operation, maintenance, disassembly or 

disposal of the device.

1.2 

Explanation of symbols

The following symbols are used in these instructions:

 DANGER

DANGER indicates an immediate hazardous situation, which, if not avoided, will result 

in death or serious injury.

 WARNING

WARNING indicates a possible hazardous situation with the risk of death or serious 

injury if it is not prevented.

 NOTICE

NOTICE indicates a situation that may cause possible damage to property if it is not 

prevented.

 NOTE

NOTE indicates tips, recommendations and important information. The notes simplify 

work, contain information on particular operating steps and help to avoid additional 

work resulting from incorrect procedures.

 

MANDATORY ACTION

This symbol denotes actions that the user must carry out.

 

RESULT OF ACTION

This symbol denotes the relevant results of actions and procedures.

1.3 

Other documents

Besides this document the following material can be found on the Internet at 

www.turck.com

:

 

Data sheet of the respective device

 

IODD file

 

IO-Link parameter manual

All the required Turck software components and the IODD can be downloaded via the Turck 

Software Manager. The Turck Software Manager can be downloaded free of charge from  

www.turck.com

.

Summary of Contents for uprox BI10U-M18 Series

Page 1: ...Your Global Automation Partner Operating Instructions Inductive Sensors uprox with IO Link Interface...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Contents...

Page 3: ...s 11 4 2 1 Properties and features Rectangular design 11 4 3 Operating principle 11 4 4 Functions and operating modes 11 4 4 1 Sensor functions 11 4 4 2 Settable properties 13 4 4 3 Standard I O mode...

Page 4: ...ction block 25 9 1 3 Process data 25 9 2 Setting in SIO mode 26 9 2 1 Setting the device before initial commissioning 26 9 2 2 Setting devices after initial commissioning 26 10 Troubleshooting 26 11 M...

Page 5: ...ch if not avoided will result in death or serious injury WARNING WARNING indicates a possible hazardous situation with the risk of death or serious injury if it is not prevented NOTICE NOTICE indicate...

Page 6: ...manual 1 4 Feedback about these instructions We make every effort to ensure that these instructions are as informative and as clear as pos sible If you have any suggestions for improving the design or...

Page 7: ...r uprox or uprox 3 Faktor 1 sensors Rated switching distance Switching distance Functional principle i Inductive Installation B Flush N Non flush M18 Design Housing M Threaded barrel brass in mm MT Th...

Page 8: ...he commission ing of your application The Turck product database offers you several software tools for pro gramming configuring or commissioning as well as data sheets and CAD files in many export for...

Page 9: ...from strong magnetic fields The devices can be operated and set with IO Link masters compliant with specification 1 1 via an IO Link interface Process and diagnostics data can be exchanged during oper...

Page 10: ...th the surrounding mounting area see chapt 5 2 All devices are provided with a metal bodied M12 connector plug for connecting the sensor cable The devices can be set and operated via an IO Link interf...

Page 11: ...ontactless and wear free detection of metallic objects To do this the devices generate an electromagnetic field which interacts with the detected object The sensors of the uprox series have no reducti...

Page 12: ...2nd bit Bit 3 0 0 0 1 1 0 3rd bit Bit 2 0 1 0 1 0 1 NOTE Output 2 can be configured as required or can be used as a temperature indicator The maximum switching frequency is reduced to 7 Hz in low reso...

Page 13: ...on Output 2 The following output configurations can be set for output 2 PNP NO contact PNP NC contact NPN NO contact NPN NC contact Push pull non inverted Push pull inverted Temperature indicator not...

Page 14: ...f the switch on delay Ton is activated the switching pulse is generated after the actual sensor actuation The switch on delay can be set between 0 60000 ms Abb 7 Switch on delay The set output configu...

Page 15: ...actual value is above or below the set limits Application specific marking The device is provided with a 32 byte memory for application specific marking The first byte of the memory is transferred to...

Page 16: ...log mode Temperature alarm for values above or below the set temperature limits Application specific marking Reading of IO Link parameter data All other sensor functions and settable features see chap...

Page 17: ...U M18 BI10U MT18 10 Nm BI20U M30 BI20U MT30 50 Nm Clean the mounting surface and the surrounding area Install the sensor in a fixture mounting bracket or fixing clamp if necessary Install the sensor o...

Page 18: ...h a half shell clamp NOTICE Mounting with a half shell clamp Device damage due to faulty mounting Align the uprox marking on the front cap of the sensor horizontally in relation to the half shell clam...

Page 19: ...from the rear or with a protrusion Clean the mounting surface and the surrounding area Install the sensor in a fixture mounting bracket or fixing clamp if necessary Install the sensor or the mounting...

Page 20: ...metal X 10 mm 20 mm X 20 mm 20 mm X 30 mm 20 mm X 40 mm 20 mm Protruded on metal Y 10 mm 40 mm Y 20 mm 50 mm Y 30 mm 50 mm Y 40 mm 50 mm Mounting in aperture plate I 150 mm Installation with twisted...

Page 21: ...ace left Active face right Active face up Active face down Gently press together the fixing clamp on the mounting bracket to release the device from the mounting bracket Turn the active face to the si...

Page 22: ...irections Active face front as supplied Active face left Active face right Active face up Active face down Undo the locking screw B and pull the sensor from the mounting bracket A Undo the screws to E...

Page 23: ...ring diagram 7 Commissioning The device is operational automatically 18 ms after the cables are connected and the power supply is switched on If the device is connected to an IO Link master IO Link co...

Page 24: ...during com missioning as well as during operation NOTE The change of the output configuration is only updated after a voltage reset or after switching to SIO mode 8 3 Operating devices in SIO mode In...

Page 25: ...0 Output 2 not actuated 1 Output 2 switches depending on the sensor function and the output configuration 1 Output 2 is not set as a temperature indicator One switch point sensor function 2 Switch po...

Page 26: ...se the device at another location in the application The sensor has a fault if it is still present Take the device out of service and replace it with one of the same type If the device operates troubl...

Page 27: ...rom the device Undo the connections of the device or if necessary the mounting aid for the mounting area Undo if necessary the connection of the device to the mounting aid 14 Disposal The devices are...

Page 28: ...age reverse polarity protection yes completely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 Switching output or IO Link mode Output 2 Switching output Switching fre...

Page 29: ...pletely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 Switching output or IO Link mode Output 2 Switching output Switching frequency max 0 5 kHz IO Link specificatio...

Page 30: ...Short circuit protection Yes cyclic Voltage drop at Ie 1 8 V Wire breakage reverse polarity protection yes completely Output function 4 wire NO contact N O contact PNP NPN Push pull IO Link Output 1 S...

Page 31: ...31 2016 08 uprox Sensors with IO Link Interface...

Page 32: ...D102217 2016 08 D102217 1608 28 subsidiaries and over 60 representations worldwide www turck com...