29
2016/08
upr
ox® S
ensors with IO
-Link I
nt
er
fac
e
15.2 Technical data – BI…U-MT…
Technical data
BI6U-MT12-…
BI10U-MT18-…
BI20U-MT30…
Rated operating distance S
n
6 mm
10 mm
20 mm
Mounting condition
flush
Assured switching distance
≤ (0.81 × S
n
) mm
Repetition accuracy
≤ 2 % of full scale
Temperature drift
≤ ± 10 %
Hysteresis
3…15 %
Ambient temperature
-25…+70 °C
Operating voltage
10…30 VDC
Ripple
≤10 % U
SS
DC rated operational current
≤ 150 mA
No-load current I
0
≤ 20 mA
Residual current
≤ 0.1 mA
Rated insulation voltage
≤ 0.5 kV
Short-circuit protection
Yes/cyclic
Voltage drop at I
e
≤ 1.8 V
Wire breakage / reverse polarity
protection
yes/completely
Output function
4-wire, NO contact/N/O contact, PNP/NPN/Push-pull/IO-Link
Output 1
Switching output or IO-Link mode
Output 2
Switching output
Switching frequency
max. 0.5 kHz
IO-Link specification
IO-Link specified according to version 1.1 and V1.0 (separate IODD)
Port class
Class A
Transfer rate
COM 2/38.4 Kbit/s
Process data width
16-bit
Switching point information
2 bit
Frame type
2.2
Design
Threaded barrel, M12 × 1
Threaded barrel, M18 × 1
Threaded barrel, M30 × 1.5
Dimensions
52 mm
52 mm
62 mm
Housing material
Metal, CuZn, PTFE-coated
Material of active face
Plastic, LCP, PTFE-coated
Max. tightening torque of housing
nuts
7 Nm
10 Nm
50 Nm
Connection
Male connector, M12 x 1
Vibration resistance
55 Hz (1 mm)
Shock resistance
30 g (11 ms)
Type of protection
IP68
MTTF
874 years acc. to SN 29500 (Ed. 99) 40 °C