V01.00 | 2020/11
33
TX707FB-P3CV01
TX715FB-P3CV01
Power supply
Rated value
24 VDC (SELV)
24 VDC (SELV)
Admissible voltage range
18…32 VDC
18…32 VDC
Current consumption at 24 VDC
Max. 0.7 A
Max. 1.2 A
Dimensions
Housing (W × H)
217 × 177 mm
450 × 295 mm
Housing (W × H)
176 × 136 mm
411 × 256 mm
Installation depth (D)
45 + 10 mm
54 + 10 mm
Weight
2.5 kg
5.2 kg
Electromagnetic Compatibility (EMC)
Radiation interference
Class A
CISPR 22,
CISPR 16-2-3
Immunity
EN 61000-4-2
Electrostatic discharge
8 kV (air electrostatic discharge)
4 kV (contact electrostatic discharge)
Radiation, high frequency, electromag-
netic fields
80 MHz …1 GHz, 10 V/m
1.4 GHz … 2 GHz, 3 V/m
2 GHz … 2.7 GHz, 1 V/m
EN 61000-4-3
Burst
± 2 kV DC power port
± 1 kV signal line
EN 61000-4-4
Overvoltage
± 0.5 kV DC power port (line to earth)
± 0.5 kV DC power port (line to line)
± 1 kV signal line (line to earth)
EN 61000-4-5
Interference from high-frequency fields 0.15…80 MHz, 1 V
EN 61000-4-6
Power frequency magnetic field im-
munity test
Housing: 50/60Hz, 30A/m
EN 61000-4-8
Voltage dips, short interruptions,
voltage fluctuations
Port: AC mains; Level:
100 % duration: 1 cycle and 250 cycles (50 Hz)
40 % duration: 10 cycles (50 Hz)
70 % duration: 25 cycles (50 Hz)
phase: 0°…180°
Test executed on the 230 VAC side of the power supply
EN 61000-4-11
Port: DC mains 0 %
duration: 10 ms 20 fields × 1 s
Test executed on the 24Vdc of the EUT
EN 61000-4-29