background image

Connecting

Connecting plug-in modules

20

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

6.4

Connecting plug-in modules

The TX700 HMIs allow the use of several optional in modules. Several module configurations
are possible.

Fig. 13: Slots for plug-in modules

Slot 2 and slot 4 are available only if the plug-in module has bus extension connector.

Each slot has three communication channels:

n

1 serial interface

n

1 CAN interface

n

1 SPI interface

NOTE

It is not possible to stack two modules that are using the same type of interface.

The following table shows, which plug-in module and how many plug-in modules can be used
at which device:

Module

Application

Max. number of modules

Interface type/
communication 
interface

Bus extension
connector

TX-CAN

CAN

n

1 for TX705

n

2 for TX707… TX721

CAN

Yes

TX-RS485

RS485/RS422

Serial

Yes

TX-RS232

RS232

Serial

Yes

TX-IO-DX06

Compact I/O

SPI

No

TX-IO-XX03

Multifunction I/O 1

TX705: TX-EXTEND or other
extension module with ex-
tension slot necessary

SPI

No

Summary of Contents for TX700FB

Page 1: ...Your Global Automation Partner Instructions for Use TX700FB HMI PLC Series for Food and Beverage...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 3: ...s 13 4 4 1 Plug in extension modules 13 4 4 2 Power supply 13 4 4 3 USB accessory 13 5 Installing 14 5 1 Installation instructions 14 5 2 Fasten devices in the mounting cutout 15 5 3 Installing plug i...

Page 4: ...YS 25 7 7 Programming with TX VisuPro 25 7 7 1 Transferring TX VisuPro to the device 26 8 Configuring 27 8 1 Configuring the system settings 27 9 Operating 29 9 1 LED displays 29 10 Troubleshooting 30...

Page 5: ...RNING WARNING indicates a dangerous situation with medium risk of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or mod...

Page 6: ...uct 2 1 Product identification These instructions apply to the following HMIs n TX707FB P3CV01 n TX715FB P3CV01 2 1 1 Type label The Type label is located on the back of the device Fig 1 Type label TX...

Page 7: ...Nopen master Fig 2 Type code TX700 2 2 Scope of delivery n TX700 n Food compliant gasket n Power supply connector n Connector for serial interface n Mounting brackets n Quick Start Guide 2 3 Legal req...

Page 8: ...mbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com For further inquiries in Germany contact the Sales and Service Team on n Sales 49 208 4952 380 n Technology 49 208 4952 390 Out...

Page 9: ...erator panels of the F B series are suitable for use in the F B industry and comply with the standards and guidelines for hygienic design DIN EN1672 2 and EHEDG FDA 21 CFR 177 2006 The devices may onl...

Page 10: ...connected via the extension slots A USB host port and an SD card slot are provided for using external storage me dia The TFT widescreen color display of the devices is designed as a capacitive multi...

Page 11: ...ules for I Os and further communication interfaces 4 3 Functions and operating modes The CODESYS V3 control of the devices has the functions PROFINET controller EtherNet IP scanner and Modbus TCP as w...

Page 12: ...100 Mbit 1 10 100 1000 Mbit n Extension slots for plug in modules 2 slots for max 4 plug in modules n Serial interface n Slot for SD card n USB port Compatible SD cards Specification Supported types S...

Page 13: ...00002599 TX RS232 Serial interface for RS232 communication 100004786 TX EXTEND Bus extension electromechanical adapter for the use of the plug in module TX IO XX03 100009535 TX UMTS Wireless modem plu...

Page 14: ...ce to direct sunlight for long periods of time to avoid overheating the device n Do not install the device in environments in which it is exposed to corrosive chemical sub stances In order to meet the...

Page 15: ...re fixed in the mounting cutout with mounting brackets Mount the brackets as follows Fig 6 Insert the brackets Tighten the fastening screws until the brackets are firmly in contact with the device The...

Page 16: ...modules 16 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 5 3 Installing plug in modules Fig 7 Installing plug in modules e g TX CAN TX IO DX06 Fig 8 Installing p...

Page 17: ...electromagnetic interference Ground the unit via the grounding screw near the power supply connection Grounding the power supply The power supply circuit may be floating or grounded To ground the sup...

Page 18: ...is of sufficient capacity to operate the device Fig 10 TX7 FB connectors Port Description 1 USB port V2 0 max 500 mA 2 Ethernet port 2 10 100 Mbit 3 Ethernet port 1 10 100 Mbit 4 Serial interface 5 Et...

Page 19: ...nnecting external devices to the serial interface The serial port is used to communicate with a PLC or with another type of device The following standards are available at the serial interface The typ...

Page 20: ...channels n 1 serial interface n 1 CAN interface n 1 SPI interface NOTE It is not possible to stack two modules that are using the same type of interface The following table shows which plug in module...

Page 21: ...MI all slots 6 4 1 Slot assignment CAN port Physical interface CODESYS parameter network Slot 1 Network 0 Slot 2 Network 0 Slot 3 Network 1 Slot 4 Network 1 6 4 2 Slot assignment serial interfaces Phy...

Page 22: ...ot use sharp or pointed objects screwdrivers etc to operate the touch screen 7 3 Initial commissioning The Ethernet ports of the device are set to DHCP by default During the initial commissioning the...

Page 23: ...via the Turck Service Tool 7 5 1 Setting the IP address via the web server Log in to the device s web server as described under Web server login Edit the network setting via System Settings Network E...

Page 24: ...ting the IP address via Turck Service Tool Connect the device to the PC via the Ethernet interface Open Turck Service Tool Click Search or press F5 Fig 16 Turck Service Tool home screen a Turck Servic...

Page 25: ...quisites n CODESYS V 3 5 14 0 and the package TXxxx HMI PLC series for the device have to be in stalled on a PC running Microsoft Windows 7 7 Programming with TX VisuPro Prerequisites n For programmin...

Page 26: ...project to a device n Via Ethernet n Via a USB stick Project transfer via Ethernet Connect the HMI device to the computer with an Ethernet network Execute the command Run Download in TX VisuPro You m...

Page 27: ...in Tap Tap mode see Recovery operation in the Adapting the system set tings 27 8 1 Configuring the system settings The available options can be selected from the navigation menu on the left side of t...

Page 28: ...ngs menu System Information about platform status and timers like System on time backlight on time Logs Activating and exporting persistent log for BSP Date Time Date and time including time zone and...

Page 29: ...splays The device has the following LED displays n Status of the Ethernet ports LED orange left LED Meaning off No Ethernet connection On Ethernet connection established LED green right LED Meaning On...

Page 30: ...the device does not function as expected first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no...

Page 31: ...eturns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloaded from https www turck de en retoure se...

Page 32: ...core 800 MHz Operating system Linux RT Linux RT Flash 4 GB 8 GB RAM 1 GB 2 GB Expansion memory USB SD card USB SD card Real Time Clock Yes battery backed Yes battery backed Accuracy RTC at 25 C 100 p...

Page 33: ...ag netic fields 80 MHz 1 GHz 10 V m 1 4 GHz 2 GHz 3 V m 2 GHz 2 7 GHz 1 V m EN 61000 4 3 Burst 2 kV DC power port 1 kV signal line EN 61000 4 4 Overvoltage 0 5 kV DC power port line to earth 0 5 kV DC...

Page 34: ...e of 40 C or higher may result in a deterior ation in the quality reliability and durability of the backlight Display viewing angles The viewing angles are included in the technical data of the respec...

Page 35: ...strial environments EN 61000 6 2 EN 61000 6 4 Food and Beverage Front panel and gasket n DIN EN1672 2 2 n EHEDG FDA 21 CFR 177 2006 UL cULus UL File No E484727 n UL 61010 1 3rd Edition and UL 61010 2...

Page 36: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100022974 2020 11 100022974...

Reviews: