Connecting
WARNING
Penetration of liquids or foreign objects through leaking connections
Danger to life due to malfunction
Fasten the M12 connectors with a tightening torque of 0.8 Nm.
Always seal unused connectors with respective protection caps.
6.1
Connecting the supply voltage and IO-Link
WARNING
Defective power supply unit
Danger to life due to dangerous voltages on touchable parts
Only use SELV or PELV power supplies in accordance with EN ISO 13849-2, which
allow a maximum of 60 VDC or 25 VAC in the event of a fault.
For the connection to IO-Link and the supply voltage, a 5-pole M12 connector is available.
Fig. 4: M12 connector for the connection to IO-Link
Connect the device to the supply voltage and IO-Link according to the pin assignment.
4
1
3
2
5
1 = 24 VDC
2 = n.c.
3 = GND
4 = C/Q (IO-Link)
5 = n.c.
Fig. 5: Pin assignment IO-Link