General information

D101925 0412 -  

BLident®

 UHF

1-2

1.3.1

Intended use

Danger

The devices described in this manual must only be used for the intended applications 
described herein and in the relevant technical description, and only in conjunction with 
certified systems and components of other suppliers.

To ensure correct and safe operation of the devices, proper transportation, storage, assembly and 
installation, as well as careful operation and maintenance must be ensured.

1.3.2

Project engineering/installation instructions

Danger

The safety and accident prevention regulations for the relevant application must be 
observed without fail.

To ensure correct and safe operation of the devices, proper transportation, storage, assembly and 
installation, as well as careful operation and maintenance must be ensured.

Summary of Contents for BL IDENT

Page 1: ...QUICK START GUIDE BL IDENT UHF SYSTEM Sense it Connect it Bus it Solve it...

Page 2: ...part of this manual may be reproduced in any form printed photocopy microfilm or any other process or processed duplicated or distributed by means of electronic systems without written permission of...

Page 3: ...which meet the requirements per IEC 60 364 4 41 or rather HD 384 4 41 S2 VDE 0100 Section 410 Fluctuations or rather deviations of the power supply voltage from the nominal value may not exceed tolera...

Page 4: ...D101925 0412 BLident UHF IV...

Page 5: ...Overview of the UHF data carriers with Impinj Monza 5 chip 6 Overview of the UHF data carriers with Alien Higgs 3 chip 7 Overview of the UHF data carriers with NXP Ucode G2XM G2XL chip 8 Overview of t...

Page 6: ...ware versions 11 3 2 2 Start up with the PIB and programmable gateways 11 3 2 3 Start up with the PIB and Siemens PLCs 12 3 2 4 The PIB_001KB function block 12 PLC_VISU visualization tab for PIB 18 3...

Page 7: ...ing indicating a potential hazard This refers to possible personal injury or death which may occur if the warning instructions are not observed The user should interpret this symbol as follows Exercis...

Page 8: ...o ensure correct and safe operation of the devices proper transportation storage assembly and installation as well as careful operation and maintenance must be ensured 1 3 2 Project engineering instal...

Page 9: ...s in the UHF range 840 960 MHz between the data carriers and the read write heads These national transmission frequencies for UHF are specified by the relevant national regulation authorities accordin...

Page 10: ...hex The second data word 2 bytes contains specific data carrier control information protocol control byte from address 10hex The actual data range of the UIIs starts at address 20hex The data carriers...

Page 11: ...riers are all factory set with the same UII these must be written individually with different UIIs before being used for the first time in applications with multiple access Figure 1 UHF data carrier m...

Page 12: ...1 Impinj Monza 3 memory area page 2 4 describes the data structure of the data carriers Table 1 Impinj Monza 3 memory area Bank address bin Bank name Memory address hex Number of bytes Comment 10 TID...

Page 13: ...memory area of 64 bytes that can be used as required The Table 2 Impinj Monza 4QT memory area private page 2 5 describes the data structure of the data carriers Table 2 Impinj Monza 4QT memory area p...

Page 14: ...ibes the data structure of the data carriers Table 3 Impinj Monza 4QT memory area public Bank address bin Bank name Memory address hex Number of bytes Comment 10 TID 10hex 1Fhex 2 Manufacturer ID mode...

Page 15: ...2 7 describes the data structure of the data carriers Table 5 Alien Higgs 3 memory area Bank address bin Bank name Memory address hex Number of bytes Comment 11 User 00hex 1FFhex 64 use as required 10...

Page 16: ...ta carriers Table 6 NXP Ucode G2XM G2XL memory area Bank address bin Bank name Memory address hex Number of bytes Comment 11 User 00hex 1FFhex 64 Only with NXP Ucode G2XM NXP Ucode G2XL has 0 bytes 10...

Page 17: ...he data carriers Table 7 NXP Ucode G2IM memory area Bank address bin Bank name Memory address hex Number of bytes Comment 11 User 00hex 27Fhex 64 use as required 10 TID 60hex CFhex 14 User TID use as...

Page 18: ...ata carriers Table 8 NXP Ucode G2IL memory area Bank address bin Bank name Memory address hex Number of bytes Comment 10 TID 20hex 3Fhex 6 Serial number 14hex 1Fhex 1 5 Model number 08hex 13hex 1 5 fi...

Page 19: ...n the devices with the TURCK BL20 BL67 and BLcompact systems Refer to the enclosed instruction leaflets of the devices for further information on the connection Figure 2 Type label on TN Q150L170 V114...

Page 20: ...cables S2500 S2501 and S2503 Overview of the TURCK BL ident UHF system D101925 0412 BLident UHF 2 12 2 6 2 LED functions of the read write heads Refer to the enclosed instruction leaflets of the devic...

Page 21: ...www turck com The BL compact device series offer compact IP67 components that enable the simple and space saving integration of RFID in your application 2 7 1 Connecting the RFID electronic modules Re...

Page 22: ...Overview of the TURCK BL ident UHF system D101925 0412 BLident UHF 2 14...

Page 23: ...write heads must at least comply with the following minimum versions Note Refer to the relevant start up manuals for a detailed description of the start up see 2 1 Support for BL ident projects page 2...

Page 24: ...o 1 if all command bits READ WRITE are 0 BUSY 1 The system is currently executing a command 0 The command execution was completed BUSY is not the inversion of DONE and in certain circumstances cannot...

Page 25: ...of the UII memory bank address 01 of the data carrier memory may cause the data carrier to permanently malfunction The following table shows the meaning of the command bits of the process output data...

Page 26: ...The BL ident system must be reset RESET or the command must be executed with a different data carrier 0 Function is not used TAG_ID 0 1 The rising edge initiates the command for reading the lowest 8...

Page 27: ...0360 TN917 Q240L280 H1147 7030398 TN865 Q280L640 H1147 7030301 TN902 Q280L640 H1147 7030306 TN902 915 Q280L640 H1147 7030367 RESET 0 1 The rising edge causes a Reset of the BL ident system If the stat...

Page 28: ...his is not possible due to a fault The read operation is not repeated The read operation has failed 2 The bypass time parameter is 1 The data carrier is to be read but this is not possible due to a fa...

Page 29: ...Table 14 Parameters of the BLxx 2RFID S RFID electronic modules page 3 9 Position of the error code Defines the position of the error code in the data image With word based fieldbus systems choose the...

Page 30: ...e modules Byte no Bit 7 6 5 4 3 2 1 0 0 reservedA Transmit power level channel 1 1 reservedA Transmit power level channel 2 2 Operation mode channel 1 Transmit frequency band channel 1 0 3 Operation m...

Page 31: ...8 the basic settings for antenna and transmission output configuration are used that are defined in the WebConfigsoftware tool B Depending on polarization 32 dBm linear 29 dBm circular C for USA and...

Page 32: ...32 dBm linear 29 dBm circular C for USA and Brazil EIRP 1 TN Q150 L170 V1147 TN Q240 L280 H1147 TN Q280 L640 H1147 0 Level 1 2 dBm 9 dBm 24 dBm 1 Level 2 5 dBm 12 dBm 27 dBm 2 Level 3 8 dBm 15 dBm 28...

Page 33: ...rammable gateways are suitable for start up with the PIB using CoDeSys Note Refer to the relevant manuals for a detailed description of the start up see 2 1 Support for BL ident projects page 2 1 Note...

Page 34: ...hest program level to be processed cyclically by the CPU To view this level choose the Blocks tab and open the display of the function block by double clicking PLC_PRG PRG see Figure 6 PIB function bl...

Page 35: ...D101925 0412 BLident UHF 3 13 Start up with the BLxx 2RFID A and BLcompact RFID electronic modules Figure 6 PIB function block Additional functions PIB function block...

Page 36: ...channel 1 Index 112 refers to channel 2 for each BL ident module of the station Deviating indices e g 113 will generate an error message OFFSET 0 This offset is added to the start address ID The calc...

Page 37: ...ytes in CH_0_RXREF The array CH_0_RXREF defines the entire memory area for the send data and comprises 1024 bytes CH_0_RXREF can be found in the Resources tab in the VarGlobe_PIB global variables fold...

Page 38: ...6 MemStatus Status of a data carrier e g memory size available capacity 7 DevStatus Status of an Ident unit 8 Next This is the command to finish operations for a transponder Table 20 In_Out parameter...

Page 39: ...e no electromagnetic field is generated TagFully Read This output value indicates with TRUE green that all data areas of the data carrier have been fully read by the BL ident system This automatic rea...

Page 40: ...Figure 7 PLC_VISU PIB visualization Start up D101925 0412 BLident UHF 3 18 PLC_VISU visualization tab for PIB...

Page 41: ...2 BLident UHF 3 19 Start up with the BLxx 2RFID A and BLcompact RFID electronic modules The following example shows the display of UIIs for two UHF data carriers Figure 8 PLC_VISU PIB visualization wi...

Page 42: ...NET Note With the Inventory command all UIIs of the accessible data carriers in the BLxx 2RFID A electronic module are collected within an automatically self adjusting time window e g max 4 seconds fo...

Page 43: ...but this is not possible due to a fault The read operation is not repeated The read operation has failed 2 The bypass time parameter is 1 The data carrier is to be read but this is not possible due to...

Page 44: ...selects from four predefined frequencies see Table 24 Parameters of the BLxx 2RFID A RFID electronic modules page 3 24 Note The WebConfig software application enables the read write heads to be compr...

Page 45: ...eter data bytes for BLxx 2RFID A inter face modules Byte no Bit 7 6 5 4 3 2 1 0 0 reservedA Transmit power level channel 1 1 reservedA Transmit power level channel 2 2 Operation mode channel 1 Transmi...

Page 46: ...5 MHz Channel 8 3 Band 4 TN865 867 5 MHz Channel 13 TN917 919 1 MHz Channel 11 Transmit power level ERP A When set to level 8 the basic settings for antenna and transmission output configuration are u...

Page 47: ...vel ERP A When set to level 8 the basic settings for antenna and transmission output configuration are used that are defined in the WebConfigsoftware tool B Depending on polarization 32 dBm linear 29...

Page 48: ...ck com www turck com D101925 0412 D101925 0412 Hans Turck GmbH Co KG Witzlebenstra e 7 45472 M lheim an der Ruhr Germany Tel 49 0 208 4952 0 Fax 49 0 208 4952 264 E Mail more turck com Internet www tu...