Start-up
D101925 0412 -
BLident®
UHF
3-22
Of the wide range of setting options available in WebConfig the following are available for
TN....Q150L170-V1147 and TN...Q240L280-H1147 – the setting options for TN...-Q280 L640-H1147 are
different:
Event handling for LEDs/buzzer/RS485
(Gen2 selection and truncate) Selection of data carriers and masking to IS0 18000-6C
(Data matching) Analysis of the UII data carrier bank
(Access) Setting the access to data carriers, e.g. with multiple access
(Frequency setup/channel mask) Used transmission frequency/channel assignment
(Inventory profiles) Selection of parameters for multiple access to the data carriers
(Link profiles) Selection of parameters in the wireless transmission protocol
The basic default settings of the read/write heads are defined as follows:
Transmit frequency band
This parameter selects from four predefined frequencies.
(see
Table 24: “ Parameters of the BLxx-2RFID-A RFID electronic modules” page 3-24
Note
The WebConfig software application enables the read/write heads to be comprehensively
parameterized and configured via a PC. We recommend the STW-RS485-USB interface
converter (Ident no. 7030354) for the connection, together with the STW-RS485-USB-PS
power supply unit (Ident no. 7030355).
The software tool is only designed for users that wish to make more extensive settings to the
read/write heads that are different to the parameter options of
BL ident®
.
Table 22:
Basic setting of
the read/write
heads
Parameter
TN....Q150L170-
V1147
TN...Q240L280-
H1147
TN...-Q280 L640-
H1147
1
= Only USA
and Brazil
(EIRP)
Transmit frequency
band
Band 1 (865.7 MHz
and 917.3 MHz)
Band 1 (865.7 MHz
and 917.3 MHz)
Band 1 (865.7 MHz
and 917.3 MHz)
ERP transmit power
level [dBm]
circular
26
29
33 (36
1
)
Note
The selection of transmit frequency band is
only
relevant for device versions with type
designations beginning with TN865-... or TN917-....