Overview of the TURCK BL ident® UHF system
D101925 0412 -
BLident®
UHF
2-6
Overview of the UHF data carriers with Impinj Monza 4 QT chip – “public” mode
Note
The following data on the Impinj Monza 4QT in “public” mode is for information purposes
only since the “public” mode is not supported by the
BL ident®
system.
The Impinj Monza 4 UHF data carriers in “public” mode have a UII memory area of 12 bytes.
The
Table 3: “Impinj Monza 4QT memory area - “public”” page 2-6
describes the data structure of the
data carriers.
Overview of the UHF data carriers with Impinj Monza 5 chip
The Impinj Monza 5 UHF data carriers have a UII memory area of 16 bytes.
The
Table 4: “Impinj Monza 5 memory area” page 2-6
describes the data structure of the data carriers.
Table 3:
Impinj Monza
4QT memory
area - “public”
Bank
address
[bin.]
Bank name
Memory
address
[hex.]
Number
of bytes
Comment
10
TID
10
hex
-1F
hex
2
Manufacturer ID + model
number
00
hex
-0F
hex
2
11 manufacturer ID
01
UII “public”
20
hex
-7F
hex
12
UII
10
hex
-1F
hex
2
Protocol control bits
00
hex
-0F
hex
2
CRC-16 checksum
00
Reserved
20
hex
-3F
hex
4
Password for memory access
00
hex
-1F
hex
4
Password to deactivate the
memory
Table 4:
Impinj Monza 5
memory area
Bank
address
[bin.]
Bank name
Memory
address
[hex.]
Number
of bytes
Comment
10
TID
30
hex
-5F
hex
6
Serial number
20
hex
-2F
hex
2
Extended TID header
10
hex
-1F
hex
2
Model number
00
hex
-0F
hex
2
11 manufacturer ID
01
UII
20
hex
-9F
hex
16
UII
10
hex
-1F
hex
2
Protocol control bits
00
hex
-0F
hex
2
CRC-16 checksum
00
Reserved
20
hex
-3F
hex
4
Password for memory access
00
hex
-1F
hex
4
Password to deactivate the
memory