7
USE AND OPERATION
34/46
561379 - IS16/02 - EN
1
1
1
2
2
3
FIG.33 FIG.34
Remove the material delivery flange (FIG.34-REF.2) and the pump (FIG.34-REF.3) by pulling the chocks (FIG.34-REF.1) from
the tie-rods.
- Mount a new pump
- Put the mixing unit back into its original position and block it.
Assembling the screw in the stator
Normally, the stator lasts half the time of the screw.
- Disassemble the pump from the machine (see above in the paragraph).
- Grip the pump and extract the screw (FIG.35).
- Grease the screw and the stator mouth with Vaseline (DO NOT USE MINERAL OILS AND GREASES, BUT ONLY
VASELINE).
- Partially insert the screw inside the flared mouth.
- Hit the pump (stator + screw partially inserted) repeatedly on a base that does not ruin the stator (e.g. a piece of wood)
(FIG.36).
D
FIG.35 FIG.36
7.8
IMPORTANT WARNINGS
The operator must be specifically trained to carry out this operation.
In particular, before opening a coupling, check the delivery flange pressure gauge to make sure there is no residual
pressure in the hoses and, in any case, when stepped on, the hoses must sag. Also make sure that there is no one
Summary of Contents for GIOTTO MONO
Page 1: ...Serial number Year USE AND MAINTENANCE MANUAL GIOTTO MONO IS16 02 561379 EN ORIGINAL ...
Page 2: ...THIS MANUAL IS PROPERTY OF TURBOSOL ANY TOTAL OR PARTIAL REPRODUCTION IS STRICTLY FORBIDDEN ...
Page 6: ...1 CE DECLARATION 6 46 561379 IS16 02 EN ...
Page 14: ...4 TRANSPORT AND HANDLING 14 46 561379 IS16 02 EN ...
Page 19: ...INSTALLATION 5 561379 IS16 02 EN 19 46 1 2 FIG 11 ...
Page 20: ...5 INSTALLATION 20 46 561379 IS16 02 EN ...
Page 36: ...7 USE AND OPERATION 36 46 561379 IS16 02 EN ...
Page 38: ...8 MAINTENANCE 38 46 561379 IS16 02 EN ...
Page 40: ...9 DEMOLITION 40 46 561379 IS16 02 EN ...
Page 44: ...10 TROUBLESHOOTING 44 46 561379 IS16 02 EN ...
Page 46: ...11 OPERATOR RESPONSIBILITY 46 46 561379 IS16 02 EN ...