A P P L I C A T I O N N O T E
E 9 T U S A G E I N I N D U S T R I A L F I E L D
A P N t 0 2 6 E 9 TU I F
E N R e v .1 . 1
T U R B O s . r .l .
D u s t F i l t e r C o m p o n e n t s
V i a C e n t r o I n d u s t r i a l e E u r o p e o , 3 3
–
T u r a t e ( C O ) I t a l y
T e l + + 3 9 0 3 6 2 5 7 4 0 2 4 F a x + + 3 9 0 3 6 2 5 7 4 0 9 2
1 5
Board Parameters
Item
Register
Access
Default
Note
Control Unit Job phase
0x0090
R
0
0=Power ON 2=Running
4=Prog. Parms 7=Prog. S/n
Digital input 1 (note
1
)
0x0097
R
1
0=Closed 1=Open
Digital input 2 (note
1
)
0x0098
R
1
0=Closed 1=Open
Digital input 3 (note
1
)
0x0099
R
1
0=Closed 1=Open
Digital input 4 (note
1
)
0x009A
R
1
0=Closed 1=Open
State of Relay 1
0x009B
R
1
0=OFF 1=ON
State of Relay 2
0x009C
R
1
0=OFF 1=ON
State of Relay 3
0x009D
R
1
0=OFF 1=ON
State of the Digital Tribo connection
0x009E
R
1
0=Connected 1=Not connected
Alarm presence
0x00A0
R
0
0=No alarm 1=Alarms
Hour counter Alarm
0x00A1
R
0
0=No alarm 1=Alarm
State of Tribo pre-alarm
0x00A2
R
0
0=No alarm 1=Alarm
State of Tribo alarm
0x00A3
R
0
0=No alarm 1=Alarm
State of Tribo peak alarm
0x00A4
R
0
0=No alarm 1=Alarm
Current output from Analog Tribo
0x00B1
R
0
microAmpere
Calculated Emission
0x00B2
R
0
x 0,01 mg/m
3
(2.00 on LCD = 200)
(
note
1
)
Reserved for future developments.
Local user interface
LCD display & messages
The E9T is provided of a local user interface with a large LCD display and a membrane keyboard.
Please read the E9T user manual for more information about settings. Icons and information are arranged as
shown in the following image:
Icon
Description
Analog Triboelectric probe enabled
Digital Triboelectric probe enabled
RS-485 Modbus communication
Local keyboard locked