Failure: During the initial operation, the water
does not rise into the intermediate chamber.
Cause: The outlet pipe(s) do(es) not match
the number of Hydrofoamers (cf. chapter
“Preparation”.
Remedy: Fit the correct outlet pipe.
Cause: Skimmer is new; the bad skimming action
of the water causes the water to not rise into
the reactor (intermediate chamber and skimmer
cup, if and when fitted) immediately.
Remedy: Wait a few hours until the conditions
for the skimmer have improved by themselves
through the bio-chemical processes.
Cause: In case of Master DOC Skimmer with more
than one Hydrofoamer: one of the Hydrofoamer
is not operational or is jammed.
Remedy: Check the function of all Hydrofoamers
and make operational, if and when necessary.
Disfonctionnement: Lors d’une première mise
en service, l’eau ne monte pas dans la chambre
intermédiaire.
Raison: Le (les) tuyau de sortie ne correspond pas
à la quantité d’Hydrofoamer, voir „Préparation“.
Solution: Placez le tuyau de sortie correspondant.
Raison: Ecumeur nouvellement installé, ce qui
explique le fait que l’eau soit difficilement
écumable et ne pénètre pas de suite dans le
réacteur (dans la chambre intermédiaire puis
dans le godet).
Solution: Attendre quelques heures, afin que les
processus biochimiques rendent l’eau écumable
par l’appareil.
Raison: Cas d’utilisation de Master DOC Skimmer
avec plus d’un Hydrofoamer, un des Hydrofoamer
n’est pas en service ou bien bloqué.
Solution: Vérifier le bon fonctionnement de tous
les Hydrofoamer.