INTERLOCK WITH NO MEMORY
With 4 sensors: the second opening is not automatic.
In order to open the door, the internal/external sensor
must be triggered when the other door is closed. If the
sensor is activated while the door is not yet closed, it
has no effect.
6.3 2 LEAVES
17
shows the ID to assign to the 950N2 units in
the network. If the two doors overlap, the one that opens
first is designated as the Master. If there is no overlap,
either of the two units can be designated as the Master
and the other as the Slave. The movement of the leaves 2
is synchronized.
------------------------------------------------------------------------------------------------------------------------------------
The internal / external door sensors and safety
devices must be connected to their own unit; all
other devices are connected only to the Master.
Connect the devices and carry out the
programming and Setup of the individual 950N2
units before activating the 2 LEAF function.
Only use the Master 950N2 to change the
operating mode.
-----------------------------------------------------------------------------------------------------------------------------------
The leaf opening / closing delay can be set in menu
2.5.5 of the KP EVO.
INTERLOCK WITH MEMORY
With 2 sensors or buttons: the second opening is
automatic.
6.4 2 INTERLOCK
18
shows the ID to assign to the 950N2 units in
the network. This configuration integrates the 2 LEAVES
function (on two double-leaf accesses) with the interlock
function. Refer to the operating modes described above.