920.1044 | 14
------------------------------------------------------------------------------------------------------------------------------------------
Logging in with the user password only allows
data to be viewed.
------------------------------------------------------------------------------------------------------------------------------------------
■
PASSWORD
This menu allows passwords to be set or modified.
To access the FUNCTIONS menu you are prompted to
enter a 4-digit password. The 950N2 has two passwords
available, with different access rights.
(
B)
B
Access per missions and passwords
---------------------------------------------------------------------------------------------------------------------------------
The user is only allowed to modify the user
password.
---------------------------------------------------------------------------------------------------------------------------------
2. DIAGNOSTICS
2.1 LEDS CHECK
I/O BOARD LEDS
Each input on the I/O board, has a LED that indicates
the physical state of the contact:
C I / O board LEDs
LED
DL1
Accessories
power on
Accessories
power off
DL2
–
DL9
Open contact
Close contact
LOGIC BOARD LEDS
The are 4 LEDs on the logic board:
D Logic board LEDs
LED
DL1
green
No USB
USB
connect
-ed
§
DL2
red
Normal
conditio
n
error
Setup
request
ed
Setup in
progres
s
DL3
blue
No
power
or
board
failure
/
Normal
conditio
n
/
DL4
yellow
Board
pa-
rameter
s the
same as
trimmer
and DIP
Switch
values
Board parameters
Different to button
trimmer and
Pressed DIP switch
values
/
Off
On
Flashing
Fast flashing