920.1044 | 13
KPEVO KEY
You can choose between:
Block
= the user must enter the user password in order to
access the menus that he is authorized to use.
Without user psw
= the user doesn’t need to enter the
user password in order to access the menus that he is
authorized to use.
CONSECUTIVE OBST.
Species the maximum number of consecutive obstacle
detections in the same direction of movement, before
stopping in an error condition.
TEST ERROR
Species the effect that the TEST will have when it detects
a safety device fault:
Disabled
= the door will remain stationary in an error
condition
Enabled
= the door will continue to operate at minimum
speed
■
ERRORS
In this menu, the display indicates any current errors that
there may be in real time.
■
WARNINGS
In this menu, the display indicates any current alerts that
there may be in real time.
■
CYCLE COUNTER
The 950N2 has two counters:
- total, non-resettable
- partial, resettable
This menu allows you to view the cycles performed by the
automation and reset the partial counter.
It is also possible to set a deadline for scheduled
maintenance according to:
- date (optional)
- number of cycles (from 1000 to 1000000)
Alert 60 will be displayed as soon as one of the two
settings (date or number of cycles) is reached.
------------------------------------------------------------------------------------------------------------------------------------
Logging in with the user password only allows
data to be viewed.
-----------------------------------------------------------------------------------------------------------------------------------
■
DATE/TIME
This menu allows you to set or modify the date, time and
turn European summer time on / off.
------------------------------------------------------------------------------------------------------------------------------------
To keep the settings even if there is no mains
power, which is necessary for the TIMER to
work correctly, a battery must be installed on
the Logic board.
-----------------------------------------------------------------------------------------------------------------------------------
■
TIMER
This menu includes all the parameters for configuring
the TIMER function. When the TIMER is enabled, the
operating mode of the door during the programmed
time bands is set automatically. A maximum of 6 daily
time bands can be defined, and an operating mode,
selected from those available, assigned to each one.
Each time band has a start time and an end time.
The time bands must not overlap.
------------------------------------------------------------------------------------------------------------------------------------
When the TIMER is enabled, the T icon appears
on the home screen. To manually change the
operating mode set by the TIMER, it first has to
be disabled. In order for the TIMER to work
correctly, a battery must be installed on the
Logic board.
-----------------------------------------------------------------------------------------------------------------------------------
In order to quickly program groups of days of the week
with the same time bands, it is possible to
simultaneously select all the days of the week (MON -
SUN) and all weekdays (MON - FRI). Once the time
bands that have been defined here have been
confirmed using the APPLY option, they will overwrite
any time bands that have already been programmed
for individual days. If it is necessary to program specific
days or periods (e.g. recurring holidays), you may use
the JOLLY function. A maximum of 6 JOLLY time bands
can be specified and an operating mode, selected from
those available, assigned to each one. Each time band
has a start time and an end time. The time bands must
not overlap. The JOLLY time bands are then assigned to
a maximum of 6 INTERVALS. An interval can be a single
day or a series of days.