![TTI Buddy BX4 User Manual Download Page 26](http://html1.mh-extra.com/html/tti/buddy-bx4/buddy-bx4_user-manual_1178748026.webp)
When alarm recording is trigged, a yellow blinking dot will be displayed on the top right corner.
Remarks for each option:
NO.:
SENSOR 1, SENSOR 2, SENSOR3.
RECORD:
Choose the channel(s) to start to record when the sensor(alarm) recording is triggered. There
are a total of 16 modes: OFF, CH 01, CH 02, CH 01+02, CH 03, CH 01+03, CH 02+03, 01+02+03, CH 04,
CH 01+04, CH 02+04, 01+02+04, CH 03+04, 01+03+04, 02+03+04, ALL.
TIP:
Information to be shown on screen. There is a dialog box for inputting the text. Maximum: 4 characters.
There are four alarm sources: A01: Sensor1, A02: Sensor2, A03: Sensor3 and OSPD: Over Speed.
LEVEL:
HIGH / LOW; High means Alarm input voltage higher than 5V, and Low means lower than 3V.
TOGGLE:
It will toggle to the camera you set in full screen automatically when sensor(alarm) is triggered.
There are a total of 5 modes: OFF, CH01, CH02, CH 03, CH04.
OUTPUT:
OFF (ON is not available yet).
BEEP:
ON / OFF.
5.8.2 Post Event Record
The DVR system can implement post-recording in modes of alarm recording and motion detection recording.
That means, the DVR system will keep recording for scheduled time after alarm recording completes.
1) Press
<MENU>
by remote to enter the DVR system menu;
2) Choose “ALARM” and press
<MENU>
to go to its sub-menu;
3) Go to “POST EVENT RECORD” and use <
> or <
> to set the post-recording time(0s, 10s, 20s,
30s, 45s, 60s, 180s available).
4) Press
<OK>
to save the setting and exit.
B u d d y B X 4
26 -