471C
7
Mounting method
Mounting pitch
Panel cutout dimensions: 92
0
+
0
.
8
×
45
0
+
0
.
6
mm
Panel thickness: 0.6
to
3.5mm
(
Degree of protection IP65)
3.6
to
10mm
(
Degree of protection IP20
)
If the material of the panel is aluminum, it may
be deformed due to its weak strength. So, it is
recommended to use the thickness of
aluminum panel sheet
with
at least 1.5mm.
Mounting pitch
(
Refer to the Right figure
)
Mounting method to panel
1
Insert the main unit fitted with the waterproof packing into the hole, from the panel
front, and insert the attached bracket to the ditch on both sides of the main unit.
Press the bracket as shown by arrow
①
until the main unit is stably stays and fix the
bracket. Do not remove it as the packing acts as stopper too. Refer to the side view
drawing of the bracket mounting shown below.
2
To fix the main unit more firm, press the back part (center part) of the bracket
indicated by arrow
②
by screwdriver, which enhances the stopper strength.
!
Caution
When the bracket is pressed by minus screwdriver, press it to the
direction as shown in arrow
②
.
The pressing of other part may cause the damage of bracket.
min.30
mi
n.
75
min.130
E
C
B
A
D
①
②
①
Push
②
Side view of bracket mounting
Top view of bracket mounting
Bracket
Panel to mount
Waterproof packing