- 8 -
⑥
Current sensor
To detect motor current, pass the V-phase motor wire through
the sensor in the direction from the power supply side to
motor side as shown by the arrow. Make sure that the
direction of the wire matches with the arrow on the top of the
current sensor. The number of times to pass the wire through
the sensor depends on the motor capacity and voltage. Refer to
the following table for the specified number.
The figure on the left shows the case where the number of
times to pass the wire through the sensor is two (2).
(Note) Refer to the connection diagrams on page 13 for the current sensor wiring and be
sure to pass through the motor wire of the correct phase which is connected with the
voltage input terminal V[2] of the TSM4000. If the wire of the other phase is connected,
or the wire is passed through in the opposite direction, the electric power cannot be
detected properly. This wiring is unrelated to the positive/reverse phase of the power
supply or of the forward/reverse rotation switching of the motor.
■ Number of times to pass the wire through the sensor
200/220 VAC motor
400/440 VAC motor
Motor
capacity
(kW)
Motor
rated
current (A)
Sensor
model No.
No. of times to
pass wire
through sensor
Motor
rated
current (A)
Sensor
model No.
No. of times to
pass wire
through sensor
0.1
0.71
TSM-U010
6
0.36
TSM-U010
12
0.2
1.4
TSM-U010
3
0.70
TSM-U010
6
0.4
2.3
TSM-U010
2
1.2
TSM-U010
3
0.75
3.6
TSM-U050
6
1.8
TSM-U010
2
1.5
6.6
TSM-U050
3
3.3
TSM-U050
6
2.2
9.2
TSM-U050
2
4.6
TSM-U050
5
3.7
15
TSM-U050
1
7.5
TSM-U050
3
5.5
22
TSM-U050
1
11
TSM-U050
2
7.5
29
TSM-U100
1
15
TSM-U050
1
11
42
TSM-U100
1
21
TSM-U050
1
15
55
TSM-U150
1
28
TSM-U100
1
18.5
67
TSM-U150
1
34
TSM-U100
1
22
78
TSM-U200
1
39
TSM-U100
1
30
107
TSM-M300
1
54
TSM-U150
1
37
132
TSM-M300
1
66
TSM-U150
1
45
160
TSM-M400
1
80
TSM-U200
1
55
198
TSM-M600
1
99
TSM-M300
1
75
270
TSM-M600
1
135
TSM-M300
1
90
320
TSM-M800
1
160
TSM-M400
1
110
384
TSM-M800
1
192
TSM-M400
1
132
254
TSM-M600
1
150
289
TSM-M600
1
200
385
TSM-M800
1
The motor rated current values in the table are for reference only.
■ Connecting the sensor cable to the main unit
Connect the sensor cable TSM4-S01 included in the package properly to the current
sensor and Shock Monitor main unit respectively. If the cable length is insufficient,
longer cables are optionally available. Refer to page 4 for the model number of the
sensor cable and contact TEM for ordering.
M
o
to
r
s
id
e
P
o
w
e
r
su
p
p
ly
s
id
e
C
o
n
te
n
ts
U
s
a
g
e
/N
a
m
e
s
S
a
fe
ty
In
st
al
la
tio
n
In
st
al
la
tio
n
In
st
al
la
tio
n
In
st
al
la
tio
n
/W
ir
in
g
/W
ir
in
g
/W
ir
in
g
/W
ir
in
g
T
er
m
in
a
ls
C
on
n
ec
tio
n
O
p
e
r
a
ti
o
n
M
ai
n
te
n
an
ce
/In
sp
ec
tio
n
Sp
ec
ifi
ca
tio
ns
D
im
en
si
on
s
W
a
r
r
a
n
ty
V-phase
Note)
Summary of Contents for TSM4000C1
Page 26: ...MEMO MEMO MEMO MEMO...
Page 27: ...MEMO MEMO MEMO MEMO...