Tsubaki TSM4000 Instruction Manual Download Page 5

- 4 - 

4. Checking the Package Contents

4. Checking the Package Contents

4. Checking the Package Contents

4. Checking the Package Contents    

Check the following about the product you purchased. 

(1)

 

Do the model number and specifications on the name plate match your order? 

(2)

 

Were there any damages suffered during transportation? 

(3)

 

Are the following contents included? (For their appearances, refer to the outer 
dimensions on page 24.) 

Shock Monitor unit (including a socket):  TSM4000 (Panel mounting type: TSM4000P) 
Current sensor: TSM-U*** or TSM-M*** 
Sensor cable: TSM4-S01 

4.1 Model number meaning (Main unit + Current sensor) 

 

The model number of the combination of the main unit and current sensor consists 
of the model numbers of the main unit and sensor as follows: 

TSM4000

TSM4000

TSM4000

TSM4000

U010

U010

U010

U010    

Model No. of the main unit 

Model No. of the current sensor (Last 4 digits of 
TSM-U010) 

 

The model number of the sensor cable indicates the cable length as follows: 

TSM4-S01 ..."01" means 1 m cable 
The TSM4-S01 sensor cable is included as an accessory. If this cable length is 
insufficient, optional cables of 3 m, 5 m, 10 m, 20 m and 30 m are available. Contact 
TEM when necessary. 

5. Part Names

5. Part Names

5. Part Names

5. Part Names    

    

   

  LCD display 

   

  LED indicators 

   

  Operation keys 

 

   

  Connector CN1 

 

   

  Connecting hooks (4) 

   

  Terminal block for wiring 

 

  LCD display 

... Shows load ratio, setting values and parameter settings. 

  LED indicators  ... Indicates that the motor is running and that the output relay is activated. 

  Operation keys  ... Keys used for switching the displayed mode or for changing parameters. 

  Connector CN1  ... Connector for using signals such as control input or analog output. 

  Connecting hooks  ... Used to connect/disconnect the main unit to/from the socket. 

For connection, fully insert the main unit until the hooks lock securely. 
For  disconnection,  press  down  the  four  hooks  simultaneously  and 
remove the main unit from the socket. 

  Terminal block for wiring ... Terminals for connecting an operational power supply, motor 

voltage, relay output, current sensor cable, etc. 

 

C

o

n

te

n

ts

 

U

s

a

g

e

U

s

a

g

e

U

s

a

g

e

U

s

a

g

e

    

/N

a

m

e

s

/N

a

m

e

s

/N

a

m

e

s

/N

a

m

e

s    

S

a

fe

ty

 

In

st

al

la

tio

n

 

/W

ir

in

T

er

m

in

a

ls

 

C

on

n

ec

tio

n

 

O

p

e

r

a

ti

o

n

 

M

ai

n

te

n

an

ce

/In

sp

ec

tio

n

 

Sp

ec

ifi

ca

tio

ns

 

D

im

en

si

on

W

a

r

r

a

n

ty

 

Main 

unit 

Socket 

 

(D-SUB connector, 15P, male) 

Summary of Contents for TSM4000

Page 1: ...who will actually use this product Keep this instruction manual safe from loss until this product is discarded This product is subject to change without prior notice Instruction Manual TSUBAKI TSUBAK...

Page 2: ...ight injury or property damage can occur Even if the instructions are followed a serious consequence may result depending on the situation Be sure to exercise due caution and follow all of these impor...

Page 3: ...ck functions and operation periodically according to the instruction manual If any malfunction is found contact your dealer for repair Do not use the Shock Monitor in an atmosphere where any corrosive...

Page 4: ...when the motor starts in order to avoid erroneous output during acceleration 3 2 Electric power detection function What is the electric power of a motor It is the amount of energy required to generate...

Page 5: ...as an accessory If this cable length is insufficient optional cables of 3 m 5 m 10 m 20 m and 30 m are available Contact TEM when necessary 5 Part Names 5 Part Names 5 Part Names 5 Part Names LCD disp...

Page 6: ...lt 7 Wiring 7 Wiring 7 Wiring 7 Wiring Complete wiring by using only the socket before attaching the Shock Monitor main unit to the socket Connect a commercial power supply of 90 to 250 VAC 50 60Hz or...

Page 7: ...through sensor Motor rated current A Sensor model No No of times to pass wire through sensor 0 1 0 71 TSM U010 6 0 36 TSM U010 12 0 2 1 4 TSM U010 3 0 70 TSM U010 6 0 4 2 3 TSM U010 2 1 2 TSM U010 3...

Page 8: ...cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit 15 cm away from an inverter a servo driver unit and their...

Page 9: ...er photocoupler input 8 2 Connector CN1 Terminal Description Contact input Non contact input X1 X2 X3 CN1 pin Nos 1 9 2 Up to eight levels can be selected by using the combination of the ON short circ...

Page 10: ...t Select 2 0 200 0 200 5 10 V 0 Load ratio Analog output 200 Contents Usage Names Safety Installation Wiring Terminals Terminals Terminals Terminals Connection Operation Maintenance Inspection Specifi...

Page 11: ...X3 2 IH 10 RST 11 CM 4 Aout 5 OV 12 Contents Usage Names Safety Installation Wiring Terminals Connection Connection Connection Connection Operation Maintenance Inspection Specifications Dimensions Wa...

Page 12: ...nput to X1 X2 and X3 5 Connect a commercial power supply to the operational power supply Do not connect the secondary side of the inverter 6 This connection diagram shows the wiring when parameter 20...

Page 13: ...status of the output relay Reset the self holding status of the output relay Return to parameter 1 Show the Test Program mode switching screen Change to the Monitor mode Change to the Monitor mode Ch...

Page 14: ...wer monitoring the displayed load ratio is a value calculated on the assumption that the selected motor capacity is 100 For torque monitoring it is a value calculated on the assumption that the rated...

Page 15: ...issues output and LED High1 illuminates Hold down the key The Low relay issues output and LED Low illuminates SET ON MOTOR LED Operation LED Operating relay Self Hold ON Shock Time Start Time Operatin...

Page 16: ...after it is started even in the Monitor mode Counting starts when the detected electric power reaches 5 or the current reaches 10 of the rated current Set the period as short as possible based on the...

Page 17: ...Reset 5 P r o c e s s 5 P r o c e s s 5 P r o c e s s 5 P r o c e s s 1 1 1 1 When 2 is selected SET Make the set data effective SET SET SET SET SET 5 P r o c e s s 2 7 Shock Time H2 1 0s 6 High2 Leve...

Page 18: ...atus of the relay output is retained The status is reset by pressing the RESET key or by an input to the RST terminal 2 Auto Reset Automatic reset The status is reset one second after the relay output...

Page 19: ...ply frequency and the frequency continues changing at the rate of 4 Hz or higher per second inhibit function is activated regardless of the inhibit time setting 2 Off The Auto Inhibit is disabled 1 PO...

Page 20: ...outputs Low High1 and High2 can be checked regardless of whether the motor is running or stopped 2 Motor Off In the Test mode the operation of the relay outputs Low High1 and High2 can be checked when...

Page 21: ...This function is especially useful when the motor is operated with stepless arbitrary frequencies Notes on torque monitoring The torque calculation value is based on the rated torque at 60 Hz In orde...

Page 22: ...ce with a correct sensor Does the V phase motor wire pass through the current sensor Other phase U phase or W phase Install the wiring properly Is the No of times to pass the wire through the sensor c...

Page 23: ...tanding voltage test remove the Shock Monitor main unit from the socket to avoid test voltage 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 14 Periodic Inspection 1 Inspect that...

Page 24: ...Contact capacity 1c contact 250 VAC 0 5A Inductive load cos 0 4 30 VDC 0 4 A Inductive load 110 VDC 0 2A Inductive load Minimum load 24 VDC 4 mA Life 100 000 times of operation Analog output signal 0...

Page 25: ...P TSM4 PR1 TSM4 PL1 Contents Usage Names Safety Installation Wiring Terminals Connection Operation Maintenance Inspection Specifications Dimensions Dimensions Dimensions Dimensions Warranty 37 46 4 45...

Page 26: ...damages 18 3 Paid warranty Even within the free warranty period if a failure or malfunction occurs in the TEM product due to any of the following causes the investigation repair shall be charged 1 Th...

Page 27: ...1 Value of upper limit 1 for process 1 80 10 Shock Time MIN 30 ms Shock Time setting for upper limit 1 1 0 H1 0 1 to 10 0 s 0 1 s 11 Output Relay 1 Self Hold Output operation mode selection High1 2 H...

Page 28: ...Ltd http tsubaki sg U S Tsubaki Power Transmission LLC http www ustsubaki com Taiwan Tsubakimoto Co http tsubakimoto com tw Tsubaki of Canada Limited http tsubaki ca Tsubakimoto Chain Shanghai Co Ltd...

Reviews: