- 23 -
16. Specifications
16. Specifications
16. Specifications
16. Specifications
Model number
TSM4000
TSM4000P
Applicable motor
Capacity
0.1 to 110 kW
Voltage
3-phase, 200/220 VAC or 400/440 VAC
Power supply
frequency
5 to 120 Hz
Operational power supply voltage
Commercial power supply 90 to 250 VAC 50/60 Hz,
90 to 250 VDC No polarity
In
pu
t
Terminals 1, 2, 3
250 VAC max. *1
Current sensor
±15 V
S
e
tt
in
g
Power
setting range
Lower limit
(Low)
-99 to 99%
Upper limit 1
(High1)
-200 to -5%
5 to 200%
Upper limit 2
(High2)
Start Time setting range
0.1 to 20.0 s
Shock Time setting range
MIN or 0.1 to 10.0 s
When the motor power supply frequency is 50 Hz or more,
the Shock Time for "MIN" is approximately 50 ms. *2
No. of processes
1 to 8
Response
1 to 50
D
is
p
la
y
Power percentage display range
-200 to +200%
Voltage display range
0 to 500 V (Resolution: 1% of motor rated voltage)
Current display range
0.01 to 999 A (Resolution: 1% of motor rated current)
Frequency display range
5 to 120 Hz
O
u
tp
u
t
Relay
contact
output
(Low, High1,
High2)
Contact
capacity
1c contact: 250 VAC, 0.5A (Inductive load cosφ = 0.4)
30 VDC, 0.4 A (Inductive load)
110 VDC, 0.2A (Inductive load)
Minimum load
24 VDC, 4 mA
Life
100,000 times of operation
Analog output signal
0 to 10 VDC
O
th
e
r
Inhibit function
[IH] or 0.1 to 10.0 s
Test function
Operation check of relays Low, High1 and High2 in
Test mode
Peak-hold function
Maximum power value during Shock Time period is
displayed.
(Disabled when Auto-Reset is set)
Power consumption
10 VA (Inrush current 5A within 5 ms)
Approximate weight
1.0 kg
Operating
environment
Ambient
temperature
0 to +50
℃
Relative
humidity
45 to 85% RH, no condensation
Altitude
1,000 m max.
Vibration
4.9 m/s
2
Atmosphere
No oil mist, corrosive gases, and dust
Mounting
DIN rail, screw mounting
Panel mounting
Note) *1. To use a 400/440 VAC motor, the optional 400 V class resistor "TSM4-PR1" is
required.
*2. When the motor power supply frequency is less than 50 Hz, the Shock Time for
"MIN" is 2 cycles of the power supply frequency + Approx. 10 ms. (Example for
the case of 50 Hz: 40 + 10 = 50 ms)
C
o
n
te
n
ts
U
s
a
g
e
/N
a
m
e
s
S
a
fe
ty
In
st
al
la
tio
n
/W
ir
in
g
T
er
m
in
a
ls
C
on
n
ec
tio
n
O
p
e
r
a
ti
o
n
M
ai
n
te
n
an
ce
/In
sp
ec
tio
n
Sp
ec
ifi
ca
tio
ns
Sp
ec
ifi
ca
tio
ns
Sp
ec
ifi
ca
tio
ns
Sp
ec
ifi
ca
tio
ns
D
im
en
si
on
s
W
a
r
r
a
n
ty