TallyMan V1.81 on | Specification
36
TM2
Internal Power Supply Specification
This is a MeanWell SP-300 Series unit. In the event of a failure the faulty item should be returned to
TSL for replacement.
The user should not attempt any repairs as this voids the PSU manufacturer’s warranty.
Manufacturer’s Specification
Model SP- 300-24
DC Output Voltage
24V
Output Voltage Tolerance
±
1%
Output Rated Current
12.5A
Output Current Range
0 – 12.5A
Ripple and Noise
150mV pk-pk
Line Regulation
±
0.2%
Load Regulation
±
0.5%
DC Output Power
300W
Efficiency
86%
DC Voltage Adjustment
20 ~ 26.4V
Input Voltage Range
88~264VAC 47~63Hz; 124~370VDC
AC Current
4A/115V, 2A/230V
Power Factor
0.9/100~240VAC
Inrush Current
18A/115V 36A/230V
Leakage Current
<
1mA/240VAC
Overload Protection
105~135% Type: Pulsing Hiccup Shutdown Reset: Auto Recovery
Over Voltage Protection
27.6-32.4V
Fan Control Over Temp Protect.
RTH1 or RTH2
>
50
C Fan On,
<
45
C Fan Off
>
70
C Output Shutdown
Temp. Coefficient
±
0.03%/
C (0~50
C)
Setup, Rise, Hold up Time
1.5s, 50ms, 20ms
Vibration
10~500Hz, 2G 10min./1cycle, Period for 60min each axis
Withstand Voltage
I/P-O/P:3KVAC I/P-FG: 1.5KVAC
Isolation Resistance
I/P-O/P, I/P-FG, O/P-FG:500VDC / 100Mohms
Working Temp. Humidity
-10
C-+50
C (Refer to O/P de-rating Curve), 20%-90% RH
Storage Temp. Humidity
-20
C~+85
C, 10%~95% RH
Dimensions
215*115*50mm Case 912
Module weight
1.2Kgs
Safety Standards
UL1950, TUV EN90950 Approved
EMC Standards
CISPR22 (EN55022), IEC1000-4-2,3,4,5,6,8,11 IEC1000-3-2 Verification
Notes:
1. All parameters are specified at 230V I/P, rated load, 25
C, 70% RH ambient
2. Ripple and noise are measured at 20MHz using a 12” twisted pair terminated with a 0.1uF and 47uF capacitor.
3. Line regulation is measured from low line to high line at rated load.
4. Load regulation is measured for 0% to 100% rated load.
Back to Top ^
Summary of Contents for Tallyman TM1
Page 1: ...TallyMan V1 81 on Introduction 1 Tallyman Controller Installation Manual...
Page 12: ...TallyMan V1 81 on Installation 12 PC TM1 2 3 3 2 5 5 Back to Top...
Page 20: ...TallyMan V1 81 on Installation 20 Back to Top PC TM2 2 3 3 2 5 5...
Page 30: ...TallyMan V1 81 on Installation 30 PC TM2 2 3 3 2 5 5 Back to Top...