Version 1.7 (June 2017)

TSI Flowmeters Ltd.

IMPORTANT – PLEASE REAd ThIS SECTION 

BEFORE USINg yOUR FLOWMASTER

4.1 PRECAUTIONS

!

It  is  important  to  think  safety  first,  especially  when 
working with pressure.

Please ensure the Flowmaster is securely attached to 
the service fitting (eg, hydrant outlet, pump, etc) before 
pressurizing.

Please consider carefully the expected system pressures 
if you plan to use a length of hose between the service 
point and the Flowmaster, as shown in figure 4.6. For 

pressures exceeding 5 bar, the weight of the Flowmaster 
may not be sufficient to ensure the meter will remain 
on the ground. If service pressure exceeds 7 bar, the 
meter at the end of a hose will move freely in the air 
and this is very dangerous.

!

!

!

Fig. 4.6 Caution! Never allow the Flowmaster to be 

used in an open-ended position. It is essential to secure 

the Flowmaster so that it cannot move about freely

10

4.2

FLOW & RESIdUAL PRESSURE MEASUREMENT

Note 1

Flow reading is generally taken after dirt and debris in 
the water stream have been exhausted and the water is 
clear.  This will typically take 10 to 20 seconds.

Note 2

Flow measurement can be taken without any attachment 
to the Flowmaster outlet. 

Note 3

When a residual pressure is required, an attachment 
such as a valve or hose length is placed  on the 
Flowmaster outlet to create back pressure.

!

!

!

1) Attach the Flowmaster to the standpipe and 
switch it on

2) Attach valve, hose, etc. to create back pressure 
and to direct water to safe location

3) Open hydrant fully so water is flowing

4) Read flow (in l.p.m.) and pressure (in bar).  When 
readings are taken, close hydrant fully

Summary of Contents for EMF-300E

Page 1: ...ie Unit 1 Portlaoise Enterprise Centre Clonminam Business Park Portlaoise Co Laois R32VK07 Ireland t 353 0 57 866 3852 e info tsi ie The Flowmaster 250 measuresthe flow rate andthe pressure at every w...

Page 2: ...Centre Clonminam Business Park Portlaoise Co Laois R32VK07 Ireland t 353 0 57 866 3852 e info tsi ie Version 1 7 June 2017 OPERATION MANUAL AND MAINTENANCE MANUAL Flowmaster 250 and Flowmaster 400 in...

Page 3: ...E SHOOTING 6 NiMH BATTERY CHARGER 6 2 HOW TO USE THE CHARGER 6 1 MASCOT CHARGE DIAGRAM 7 ACCESSORIES 7 2 TRANSPORT STORAGE CASE 7 1 BALLVALVE WITH BS INST M F FITTINGS 7 4 FLOW MONITORING SYSTEM 7 3 A...

Page 4: ...in components of the Flowmaster 1 4 1 1 INTRODUCTION The Flowmaster is now used by most UK and Irish fire services and has been exported to 50 countries The Flowmaster meets the requirements of the JO...

Page 5: ...in the sensor 9 Flashes on and off to indicate there may be dirt on the electrodes Ignore this signal when there is no water in the sensor 1 8 9 2 3 5 6 4 7 EXPLANATION OF USER PANEL 1 3 APPLICATIONS...

Page 6: ...esistant ADC6 12 JIS aluminium anodised Pressure rating 49 bar Digital LCD display gauge 4 digits 17 6mm high digits Analog bar graph Internal backlighting Type Bourdon Tube Range 0 10 bar 1 0 7 0 15...

Page 7: ...display in flow measurement mode is as shown below Fig 3 3 Flow meter display when ready for flow measurement and there is no water in the pipe Note the flashing symbols on the left side of the flowm...

Page 8: ...e second and then releasing 4 Figure displayed will automatically re set to zero The flow meter has a built in totalising function The volume of water that has passed through the flow meter is totaled...

Page 9: ...for static and residual pressure measurements and for flow measurements is supplied on the following pages This information is provided for guidance only It is preferential that the Flowmaster user fo...

Page 10: ...and this is very dangerous Fig 4 6 Caution Never allow the Flowmaster to be used in an open ended position It is essential to secure the Flowmaster so that it cannot move about freely 10 4 2 FLOW RES...

Page 11: ...water begins to drain from the ball valve Close the ball valve 5 When reading is taken close hydrant fully 4 Read static pressure in bar 6 Open the ball valve to exhaust pressure from the meter and s...

Page 12: ...in the red casting on the other side of the Flowmaster Connect the battery charger to one of the two sockets Plug the charger into mains Please refer to the battery charger instruction manual document...

Page 13: ...speaking if battery voltage falls below 6 volts DC it will not recover 5 3 TROUBLE SHOOTING INCOMPLETE SELF TEST SEQUENCE Display goes through the Self Test Sequence until this display 5 3 1 SCALE AD...

Page 14: ...Version 1 7 June 2017 TSI Flowmeters Ltd 6 NiMH BATTERY CHARGER 6 1 MASCOT CHARGE DIAGRAM 6 2 HOWTO USETHE CHARGER 14...

Page 15: ...S 7 1 BALLVALVE WITH BS INST M F FITTINGS The ball valve facilitates speedy and safe static pressure readings and creates back pressure for taking flow and residual pressure measurements 7 2 TRANSPORT...

Page 16: ...be quickly and easily generated using the accompanying Flow Monitoring Software Up to 6 hours of data can be captured at 1 second intervals Flowrates can be set that automatically start and stop the d...

Page 17: ...gations hereunder If Warrantor elects to comply with this warranty by means of such refund as a condition precedent to such compliance the claimant shall return such equipment toWarrantor free and cle...

Page 18: ...lowmaster Model 250 to which this documentation relates is in conformity with the provisions of the following directives 2001 95 EC General Product Safety 2006 95 EC Low Voltage Directive LVD 2004 108...

Page 19: ...Flowmeter Calibrated Type of Meter TSI Model EMF 300A Magflow Serial No Date of Calibration Method of Test Comparison with Master Flowmeter The zero offset was adjusted to read 0 lpm Since this is the...

Reviews: