baws002-gbr-0
TSCHAN
®
-S SD-5
- 17 -
9.1 Check of Direction of Rotation
§
Danger of injuries!
§
Disconnect the drive before carrying out any work on the cou-
pling!
§
Secure the drive against unintentional re-start and rotation!
§
Improperly tightened screws may cause parts to fly off what leads
to most serious personal injuries and property damages!
§
Before starting up the equipment, install all protective guards in
order to avoid unintentional contact with freely moving or rotating
parts.
§
To avoid sparks, the covers for couplings used should be made
of stainless steel!
§
The covers have to comply with protection type IP2X as a mini-
mum.
§
The cover shall be designed to prevent dust from depositing on
the coupling parts.
§
The cover must not touch the coupling and impair the proper
function of the coupling.
•
Remove the fastening bolts of the
claw ring (Fig. 9).
•
By using clamping screws, firmly
tighten the claw ring, part 366,
against the flange of the coupling
hub, part 200. A gap must result
between claw ring, part 366, and
flange hub, part 361, so that these
parts no longer contact each other.
(Fig. 9)
•
Attention!
•
Make sure that the shaft ends cannot move axially while checking
the direction of rotation.
•
The rotating coupling half must not contact the stationary coupling
half!
•
After having checked the direction of rotation, remove the clamping screws and mount the
claw ring, part 366, to the flange hub again by using the fastening elements. Pay attention
to assemble the parts in their original position.
Attention!
The contact surfaces of claw ring and flange hub must be clean, dry and free of
grease. Balanced parts are match marked to each other.
Fig. 9